8. MAINTENANCE
WARNING!
Before any work on the
appliance, disconnect all
poles of the appliance from
the power supply.
The water heater requires no special
maintenance. The anode rod helps
protect the tank against corrosion.
Depending on the water condition, the
magnesium anode rod may need to be
changed every 2 years. Galvanic and
electrolytic corrosion can damage the
tank if the anode rod worn out. Rusty
water is usually an indication of a worn
out anode rod. If rusty water is present,
you must call the authorized
professionals immediately for it to
examine anode rod and replace if
necessary.
The thermal fuse which based in the
thermostat, cuts both phases and leaves
the water heater without voltage; protect
the appliance from excessive electric due
to a possible thermostat fault, If this case
occurred, you must call the authorized
professionals for it to be repaired.
N
L
E
T1
T2
T3
T4
1
2
3
4
1
Connected to main electric supply
main switch
2
Cable
3
Thermostat base
4
Heating indicator lamp
The manufacture reserves
the right to modify the
characteristics and
specifications of its products,
without prior notice.
8.1 Draining the appliance
WARNING!
Hot water may escape
during the draining process.
To drain the water from the electrical
storage water heater:
1. Disconnect the water heater from
power source.
2. Close the inlet water source from
service valve.
3. Disassemble inlet water hose from
cold water inlet pipe of the appliance.
4. Open the hot water tape the water
will drain off the inlet pipe.
9. WHAT TO DO IF
Certain problems are due to lack of simple maintenance or oversights, which can be solved
easily without calling the service technicians, before contacting the local service centre
please carry out the check listed below.
ENGLISH
9
Summary of Contents for EYE030S1WE
Page 87: ...HRVATSKI 87 ...