Problem
Possible causes
Solution
Water leaks
Improperly sealed, hot or
cold water source connec‐
tions.
Tighten threaded connec‐
tions.
No hot water
No power to heater.
Turn on electrical switch,
Check for blown fuses or
tripped breaker.
Insufficient hot water
Cold water mix fast with
appliance stored hot water,
high water source pres‐
sure.
Close the inlet water serv‐
ice valve(or the pressure
regulator) partially until the
problem disappear.
Wrong piping connections. Correct piping.
Wasted hot water.
Review and reduce hot
water consumption.
Long runs of exposed pipe. Insulate piping.
Hot water piping on out‐
side wall.
Insulate piping.
High operation cost (power
consumption)
Wrong piping connections. Correct piping.
Wasted hot water.
Review and reduce hot
water consumption.
Long runs of exposed pipe. Insulate piping.
Hot water piping on out‐
side wall.
Insulate piping.
Leaking Taps.
Repair leaking taps.
Dripping from safety valve High water source pres‐
sure.
Install a 3 or 4 bar pres‐
sure regulator valve in the
mains connection of the
house.
Brown (rusty) water from
outlet
Brown or rusty water indi‐
cates a worn out anode
rod
Call authorized professio‐
nals for anode rod exami‐
nation and replace it if nec‐
essary
10. TECHNICAL DATA
10.1 Details on energy
consumption
Product data complies with EU
regulations relating to the Directive on
the ecodesign of energy related products
(ErP).
www.electrolux.com
10
Summary of Contents for EYE030S1WE