INSTALLATION

5.1

Select the location and hang 

up the shower

While planning your shower installation, 
make sure you allow sufficient clearance 
between the ceiling and walls to allow any 
future maintenance (cleaning the filter etc.) 
to be performed.

Water entry position:

Remain a proper distance between the top 
of the unit and the ceiling to access cover 
screws.
Position the unit where it will NOT be in 
direct contact with water from the 
showerhead. Position the shower unit 
vertically. The shower should be 1m 
minimum height from floor.
Take the proper water and cable entry 
position into consider while selecting the 
installation position. See Fig. 1 for the water 
and cable entry position options.
Fig. 1

Before installation, make sure 
you read through the electrical 
requirements and water 
requirements section.

WARNING!

1

2

3

4

5

6

7

8

Bottom right inlet entry

Rear right inlet entry

Right inlet entry

Summary of Contents for EYL10566BT

Page 1: ...EYL85066BT EYL95066BT EYL10566BT WATER HEATER USER MANUAL ...

Page 2: ...s every time Welcome to Electrolux Visit our website to Get usage advice brochures trouble shooter service information www electrolux com Register your product for better service www electrolux com productregistration Buy Accessories Consumables and Original spare parts for your appliance www electrolux com shop 2 SAFETY INSTRUCTIONS 6 3 ELECTRICAL REQUIREMENTS 8 1 SAFETY INFORMATION 4 4 WATER REQ...

Page 3: ...ase visit www electrolux co uk Please ensure you read the information under What to do if in your instruction booklet before contacting us for service Servicing and or installation of your product including electrical connections and water connections should be carried out by a suitably qualified engineer In the user manual and on our web site www electrolux co uk you will find some useful informa...

Page 4: ...and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved 1 SAFETY INFORMATION 1 1 Children and vulnerable people safety 1 2 General Safety Keep all packaging away from children Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Before mai...

Page 5: ...ion must be incorporated in the fixed wiring in accordance with the wiring rules The fixed wiring insulation must be protected for example by insulating sleeving having an appropriate temperature rating This appliance is designed to be used for shower only Do not try to use for other purpose It may cause potential harm to person or the appliance This appliance is only designed for household use or...

Page 6: ...ips and contactors Always switch off the power at the consumer unit and isolate the electrical supply before making any electrical connections or if you have to remove the cover of an installed unit Risk of fire and electrical shock Remove all the packaging labeling and protective film if applicable before first use Obey the installation instruction supplied with the appliance Keep the minimum dis...

Page 7: ... during use or if the water is leaking from the shower unit itself Turn off at the mains electrical supply and refer to the Troubleshooting section see page 23 or contact Electrolux Customer Services see page 3 Do not crush or kink the shower hose this could damage the hose cause leaks and activate the pressure relief device Contact your municipal authority for information on how to discard the ap...

Page 8: ...ng above 9kW it is advisable to contact the local electricity supply company The shower must be connected to its own independent electrical supply It must not be connected to a ring main spur power socket or lighting circuit The electrical supply must be adequate for the loading of the unit and existing circuits Check your consumer unit main fuse box has a main switch rating of 80A or above and th...

Page 9: ...f the cable or conduit Unit Rating 240V Circuit Protection Device MCB Cartridge Fuse 8 5kW 9 5kW 10 5kW 40A 45A 40 45A 45A 45A 45A Cable current carrying capacity table for twin and earth PVC insulated cable Current carrying capacity In an insulated wall In conduit or trunking Clipped direct or buried in a non insulated wall A 6 4 m m 6 A 8 3 m m 6 A 2 3 m m 6 10mm 43A 10mm 52A 10mm 63A Note Cable...

Page 10: ...vent back flow It is required that the showerhead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance If the shower is to be installed in a hard water area we recommend that an in line scale inhibitor is fitted which will prolong the life of the shower ...

Page 11: ...cess cover screws Position the unit where it will NOT be in direct contact with water from the showerhead Position the shower unit vertically The shower should be 1m minimum height from floor Take the proper water and cable entry position into consider while selecting the installation position See Fig 1 for the water and cable entry position options Fig 1 Before installation make sure you read thr...

Page 12: ...the wall Using the installation template supplied mark the positions of the three fixing holes To mark the drilling position Check if there is any buried pipes or cables before drilling CAUTION NOTE Ensure that there are sufficent lengths of supply pipe and electrical cable to reach the connection points as shown on the template Remove the installation template and drill the fixing holes dimension...

Page 13: ...en the screws at this stage The fixing holes are elongated to allow for out of square adjustment after the plumbing connection has been completed Unscrew the water inlet cover fixing screws and pull the water inlet cover out Fig 4 Unscrew the screws that fixing the front cover Fig 2a and pull out the front cover lightly then disconnect the cable between front cover and the chassis Fig 2b after tha...

Page 14: ...ents Fig 5 Turn on the mains water supply and check for leaks in the pipework connection to the shower NOTE At this stage no water can flow through the unit To check the water supply leak NOTE 21mm Fig 5 14 www electrolux com This Electrolux shower heater has 2 wiring terminals and 2 earthing terminals shown as Fig 6 You can choose the proper terminals when connecting the wiring Fig 6 Wiring termi...

Page 15: ...le the water inlet cover Fig 8a and reconnect the cable Fig 8b 4 Check to ensure that the wiring is not trapped and replace the cover squarely to the backplate and guide into position so that the knobs locate correctly into the splined spindles Should any difficulty arise recheck the points above 5 While applying slight pressure to the cover secure in position with the retaining screws 6 Once you ...

Page 16: ...Use the flexible hose to locate the proper position for the bracket if necessary Put the wall plugs on the holes then remove the sliding rail holder covers from the sliding rail holders and fix one of the sliding rail holders on the upper position then replace the sliding rail holder cover 3 Check if there is any buried pipes or cables before drilling WARNING NOTE When fixing the sliding rail hold...

Page 17: ...push on water flowe out when push off water stops NOTE When you press the On off button to start the unit water start to flow out from the showerhead To avoid too hot or too cold water flow do not let showerhead point directly to human body 6 1 Product features 3 4 2 3 1 4 2 Water temperature adjuster This section is used to select the desired water temperature The water temperature can be adjuste...

Page 18: ... Mix position as shown on Fig 15 3 Turn on the mains water supply to the shower at the isolating stopvalve and then turn on the electric supply to the shower at the isolating switch CAUTION Failure to turn the water flow knob to the minimum flow position MAY cause the PRD Pressure Relief Device to operate CAUTION Before first use Fig 15 Fig 14 Fig 16 4 Press the On off button and wait until water ...

Page 19: ...erature to stabilise after changing the setting temperature NOTE Adjusting the water flow will not change the water temperature setting but it may need some time for the water to be stable again The water flow can be adjusted by the water flow controler The water flow controler can be rotated within 300 To increase the water flow turn the water flow controler clockwisely To decrease the water flow...

Page 20: ...ription Setting Water flow Description Setting Water flow Description Setting Concentrated spray impact with pulse effects suitable for part pulse massage on muscle Shower spray with massage feeling Have a broader area suitable for large area shower plus spray water 6 4 Shower head setting 20 www electrolux com ...

Page 21: ...in order to maintain the performance of the shower Before removing the filter turn off the main water supply of the shower To remove the filter see Fig 18 below You can use a clean cloth to wipe the front panel Do not use brushes emery paper or burnishes to clean the unit because it may cause damages While cleaning the front panel Do not use a chemically treated cloth or duster to clean the unit D...

Page 22: ...PRD as product s pressure relief device when external factors like handset block happens and causes heater can not stand the internal pressure When reaches the highest limit PRD will break up to release water pressure and water flows out from the breaking up point to release pressure and provide protection Error code PRD Pressure Relief Device The unit is fitted with a non resettable thermal cut o...

Page 23: ...low rate via water flow controler Check if stop valves are fully open Check if a blockage in the inlet filter Blocked showerhead clean or replace blocked sprayplate in showerhead Reduce the setting temperature via temperature adjuster See Water too hot causes and their appropriate action cures If it continues contact Electrolux Customer Service Have unit checked by suitably qualified electrician o...

Page 24: ... Clean or replace blocked sprayplate in showerhead and then fit new PRD Check for free passage through hose Replace the hose if necessary and fit new PRD Fit new PRD Commission unit with showerhead removed Replace start stop switch Replace solenoid valve NOTE Identify the cause of operation before fitting a new PRD unit When fitting a new PRD follow the commissioning procedure In the unlikely even...

Page 25: ...5519W17172 000 001 www electrolux com shop ...