Power off

 

Power down the product by gently touching the 

ON/OFF icon on the center of the product.

Air speed control

 

Change the fan speed by gently touching fan icon 

on the product. If the product is in AUTO mode, it 

will switch to manual mode on touching the fan 

icon. (ref. picture 7).

UV-C emitter control

 

Activate the UV feature by gently touching UV 

icon on the product, and the UV-C emitter will 

light on. The UV-C emitter can help eliminate 

bacteria in the product. (ref. picture 8).
Touch the button again to turn off the UV feature.

11

7

8

AIR QUALITY INDICATOR

The appliance has an air quality sensor that 

analyzes the air quality.
The air quality light will show the real-time air 

quality through different colors of light. As shown 

below:

12

LIGHT'S COLOR

Blue

Green

Orange

Red

PM 2.5 (μg/m

3

)

AIR QUALITY

0-15

Very Good

16-35

Good

36-75

Bad

>75

Very Bad

FILTER CHANGE INDICATOR

The filter change indicator will light up to 

remind you to change the filter.

• When filter change indicator flicker with red 

light, please replace the filter and reset the filter 

change indicator.
• When filter change indicator stop flicker and the 

red light fix, please replace the filter immediately 

and reset the filter change indicator. 

13

14

Filter change indicator reset operation

 

Press the ON/OFF button " " for 5s and filter 

change indicator will reset, then red light will go 

off.

Auto mode

 

Chose the AUTO mode by gently touching "A" icon 

on the product. In AUTO mode the unit will adjust 

operation according to latest air quality (PM2.5 

level).  (ref. picture 9).

Sleep mode

 

Chose the SLEEP mode by gently touching " "  

icon on the product. In SLEEP mode unit will 

operate at the low noise level and all indicators 

except for SLEEP icon will go off. (ref. picture 10).

9

10

16

UV change indicator reset operation

 

Press UV icon “UV” for 3 seconds and UV change 

indicator will reset, then white light will go off.

UV-C EMITTER REPLACEMENT

The UV indicator will blink to remind you to 

change the UV-C emitter. 

Please replace the UV-C emitter as following 

steps (ref. picture 11) and reset the UV change 

indicator.
Caution: The appliance must be disconnected 

from the supply before replacing the UV-C 

emitter.

1. Open the product by rotating the base in 

anticlockwise direction with the handle 

provided at the bottom.

2. Remove the filter from the unit.
3. Grasping the UV-C emitter with a clean cloth 

or a tissure and rotating it in anticlockwise 

direction carefully.

5. Replaced the new UV-C emitter by rotating it in 

clockwise direction carefully.

6. Install the filter and base back to the unit, make 

sure they are securely in place.

15

Caution: Please ensure the filters are correctly 

inserted in the filter compartment, the equipment 

is installed on a level surface and the power plug 

is firmly connected.

OPERATION

Connect the power plug.
Power on

 

Power on the product by gently touching the ON/

OFF icon on the center of the product (ref. picture 6).

Install the filter

 

Carefully insert the filter back into the product 

without the plastic packaging (either end of the 

filter works). Take care that the filter is placed in 

the center of the cavity (ref. picture 3).

Close the base

 

Close the product by rotating the base in 

clockwise direction with the handle provided at 

the bottom till it is securely in place. (ref. picture 4).

5
6

3

4

Summary of Contents for FA31-203BL

Page 1: ...FLO A3UV01_210511 W A3 Instruction Book Models FA31 203WT FA31 203PK FA31 203GN FA31 203BL ...

Page 2: ...ack N Filter inside O UV C emitter inside Control panel F Fan speed indicator G Power on off H Fan speed control I Air quality indicator J Filter change indicator K UV button indicator L Auto mode button indicator M Sleep mode button indicator DESCRIPTION OF YOUR AIR PURIFIER FLOW A3 EN UV C kill bacteria on over filter 12 hours ...

Page 3: ...www electrolux com 3 1 4 7 2 5 8 3 6 9 10 11 3 4 5 ...

Page 4: ...abels for flammability and other warnings Do not let water or any other liquid or flammable detergent enter the appliance to avoid electric shock and or a fire hazard Do not touch the fan blade when removing the filter Children and Vulnerable People Safety WARNING Risk of suffocation injury or permanent disability This appliance is not intended for use by persons including children with reduced ph...

Page 5: ... the unit or other property Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups Do not climb on or place objects on the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the unit at the power source when it will not be used for an extended period of time Operate the unit with air filter in place Do not block ...

Page 6: ...cture 9 Sleep mode Chose the SLEEP mode by gently touching icon on the product In SLEEP mode unit will operate at the low noise level and all indicators except for SLEEP icon will go off ref picture 10 9 10 16 UV change indicator reset operation Press UV icon UV for 3 seconds and UV change indicator will reset then white light will go off UV C EMITTER REPLACEMENT The UV indicator will blink to rem...

Page 7: ...ipment operates normally but the outgoing air volume is significantly reduced If the fault encountered is not listed above please call the Customer Service Hotline When fault indicators show that the system is not operating properly perform the following check Commonly Asked Questions Topics Carry out the operations below for commonly occurring questions or faults NO Power cord issue Filter compar...

Page 8: ......

Page 9: ...www electrolux com 3 1 4 7 2 5 8 3 6 9 10 11 3 4 5 ...

Page 10: ... านฉลากผลิตภัณฑ ส ำหรับข อมูลเกี ยวกับการติดไฟและ ค ำเตือนอื นๆ ระมัดระวังอย าให น ำ หรือของเหลวประเภทอื นๆ หรือน ำยาท ำความสะอาดที ติดไฟได เข าไป ในเครื องเพื อหลีกเลี ยงความเสี ยงในการถูกไฟฟ าช อต และ หรือเกิดเพลิงไหม ห ามสัมผัสใบพัดลมขณะถอดแผ นกรอง ความปลอดภัยของเด กและผู ที มีความเสี ยง ค ำเตือน เสี ยงต อการขาดอากาศหายใจ ได รับบาดเจ บ หรือทุพพลภาพถาวร เครื องใช ไฟฟ านี ไม ได มีไว ส ำหรับใช งาน...

Page 11: ...ดเครื องจากแหล งจ ายไฟหากคาดว าจะไม ได ใช งานเครื องเป น เวลานาน ใช งานเครื องในขณะที ประกอบแผ นกรองอากาศอยู ห ามปิดกั นหรือครอบตะแกรงรับลมเข า บริเวณช องปล อยอากาศ และช องระบายอากาศ ตรวจสอบให แน ใจว าวางตัวเครื องไว ห างจากอุปกรณ ไฟฟ า อิเล คทรอนิกส 30 ซม ใช งานผลิตภัณฑ นี ร วมกับอุปกรณ เสริมที มาจากผู ผลิตและ ตัวแทนฝ ายบริการเท านั น ผลิตภัณฑ จะปิดเอง หากผลิตภัณฑ เอียงไปในทิศทางใดๆ และ เกิน 30 1...

Page 12: ...ep เมื ออยู ในโหมด Sleep เครื องจะท ำงานด วยระดับเสียงที ต ำและไฟแสดงสถานะ ทั งหมด ยกเว นไอคอน SLEEP จะดับ ดูรูปที 10 11 ปิดเครื อง แตะไอคอน ON OFF ที อยู ในต ำแหน งกลางเครื องเบาๆ เพื อปิดเครื อง ไฟแสดงคุณภาพของอากาศ 12 ผลิตภัณฑ นี มีเซ นเซอร วัดคุณภาพอากาศซึ งท ำหน าที วิเคราะห คุณภาพอากาศ ไฟแสดงสถานะคุณภาพอากาศจะแสดงระดับคุณภาพอากาศ แบบเรียลไทม ด วยสีของไฟแสดงสถานะที แตกต างกันไป ดังแสดงด านล า...

Page 13: ...สอบรายการต างๆ ดังนี ค ำถามที พบบ อย และความผิดปกติต างๆ ในกรณีที ท านมีข อสงสัยหรือพบอาการผิดปกติ ให ปฏิบัติตามขั นตอนดังต อไปนี ข อสงสัย หรืออาการผิดปกติ สาเหตุที เป นไปได การแก ไขปัญหา เหตุผล ล างท ำความสะอาดแผ นกรอง อากาศได หรือไม ไม ได เปลี ยนแผ นกรองอากาศใหม เท านั น แผงควบคุมไม ท ำงาน สายไฟมีปัญหา ช องใส แผ นกรองอากาศมีปัญหา มอเตอร พัดลมท ำงานผิดปกติ 1 ตรวจสอบให แน ใจว าเสียบสายไฟเข ากับตัว...

Page 14: ......

Reviews: