or 4B. POWER CORD CONNECTIONS
(3-Wire Connection Instructions . For existing installations ONLY
- Refer to Fig. 13).

1.

Follow the manufacturer’s installation instructions supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).

2.

Insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).

IMPORTANT NOTE: 

 DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed.

3.

Make sure all connections are tightened securely and replace the rear
access cover (See Fig. 9).

Grounding Instructions (3-Wire Connections only):

 

A ground

strap is installed on this range which connects the center terminal of the
terminal block (Neutral) to the range chassis. The ground strap is
connected to the range by the center, lowest screw (See Fig. 13). The
ground strap must not be removed unless National, State or Local
Codes do not permit use of a ground strap.

NOTE:

  If the ground strap is removed for any reason, a separate

ground wire must be connected to the separate ground screw attached
to the range chassis and to an adequate ground source.

NOTE: 

 

Non-terminated field wire compression connections must be

set at 22 in./lbs. or greater. Always use 10 gauge wire or larger.

Fig. 13

4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS.

3 - Wire Permanent Connection - follow Steps 1,2 & 5 below.
4 - Wire Permanent Connection - follow Steps 1 thru 5 below.

Before wiring the range, review the suggested power source location
drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):

1.

(3 & 4 - Wire Permanent Connections)

 Follow the manufacturer’s

installation instructions supplied with the strain relief and install.

2.

(3 & 4 - Wire Permanent Connections)

 Strip insulation away from the

ends of the permanent wiring for Line 1, Line 2, Neutral (also strip ground
wire on 4-Wire Connections). Tighten all 3 wire leads to the terminal
block (Follow wire locations shown in Fig. 14).

IMPORTANT NOTE: 

 DO NOT LOOSEN the factory installed nut

connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3
nuts are loosened or removed. 

NOTE: For 3-Wire Permanent

Connections skip Steps 3 & 4 and continue with Step 5.

3.

(4-Wire Permanent Connection ONLY) 

Disconnect the ground strap.

Remove the factory installed ground screw & plate to release the
factory installed copper ground strap from frame of the appliance.
Cut and discard the copper strap from the terminal block. KEEP the
ground screw, ground plate and go to Step 4.

4.

(4-Wire Permanent Connection ONLY)

 Connect the ground wire lead

(Green) to the frame of the appliance using the ground screw & plate as
shown in Fig. 15. Be sure to install using the same hole in the frame
where the ground screw was originally installed.

5.

(3 & 4 - Wire Permanent Connections)

 Make sure all connections are

tightened securely and replace the rear access cover (See Fig. 9).

Fig. 14

5. CAREFULLY SLIDE RANGE INTO FINAL LOCATION.

Be sure to provide all the adequate clearances and dimensions  shown in
Figs. 1, 2 & 3 before moving appliance into final location.

Carefully slide range into final position while inserting rear leveling leg into
and FULLY ENGAGING THE ANTI-TIP BRACKET (See Fig. 7). Make sure the
power cord folds into the remaining open floor area behind the range Warmer
or storage drawer. Be sure to check the level of the range.

Fig. 15

4

INSTALLATION INSTRUCTIONS FOR FREESTANDING ELECTRIC RANGE

Note: Non-terminated field wire compression

connections must be set at approximately 22in./
lbs. Always use 10 ga. wire or larger.

Summary of Contents for FFEF3011LW

Page 1: ...EDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5 BEYOND THE BOTTOM OF THE CABINETS p n 316454912 rev A If the information in this manual is not followed exactly a fire or electrical shock may result causing property damage personal injury or death Important Notes to the Installer Readallinstructionscontainedintheseinstallationinstructions before installing range Remove a...

Page 2: ...ll Need Power Supply Cord or Copper Electrical Wiring Metal Conduit for hard wiring NORMALINSTALLATIONSTEPS 3 16 pilot hole 1 3 4 deep The screws provided may be used in wood or concrete material Use a 5 16 nut driver or flat head screwdriver to secure the bracket in place See Fig 6 1c Level and Position Range Level range by adjusting the 4 leveling legs with a wrench NOTE A minimum clearance of 1...

Page 3: ... Instructions Refer to Fig 12 Before wiring the range review the suggested power source location drawing in Fig 3 If connecting to a 4 Wire electrical system new branch circuit or mobile home requires 4 Wire connection 1 Follow the manufacturer s installation instructions supplied with the strain relief and install Also see Figs 9 10 11 2 Insert the end connectors for Line 1 Line 2 and Neutral and...

Page 4: ... installation instructions supplied with the strain relief and install 2 3 4 Wire Permanent Connections Strip insulation away from the ends of the permanent wiring for Line 1 Line 2 Neutral also strip ground wire on 4 Wire Connections Tighten all 3 wire leads to the terminal block Follow wire locations shown in Fig 14 IMPORTANT NOTE DO NOT LOOSEN the factory installed nut connections which secure ...

Page 5: ...MAS AFUERA DE LA PARTE INFERIOR DE LOS ARMARIOS English Pages 1 4 TODAS LAS ESTUFAS PUEDENVOLCARSE SEPUEDENCAUSAR LESIONES INSTALE EL DISPOSITIVO ANTIVUELCOINCLUIDO CON LA ESTUFA VEALASINSTRUCCIONES DEINSTALACION Fig 1 Fig 2 Fig 3 Sinosesigueestrictamentelainformaciónde este manual se puede producir un incendio o un choque eléctrico que cause daños materiales lesiones corporales o fatales Notas Im...

Page 6: ...ELECTRICOS DE CONEXION Este artefacto debe ser instalado y puesto a tierra en forma correcta por un técnico calificado de acuerdo con el Código Nacional de ElectricidadANSI NFPANo 70 últimaedición ylosrequerimientos del código local de electricidad Este artefacto debe ser conectado mediante cableado permanente o el Juego de Cable de Alimentación Eléctrica Cuando instale el cableado permanente no d...

Page 7: ...o de cable Juego de cable Cableado Permanente 1 3 8 1 3 8 1 1 8 1 3 8 40 50 Amp 50 Amp 8 8 16 5 KW 7 9 12 5 KW 16 6 22 5 KW 12 6 18 5 KW Fig 10 Cubierta de acceso trasera Disco removible de 29mm de diám Ver Tabla Agujero de 22 mm de diám Ver Tabla Placa de montaje Agujerode 35 mm de diám Ver Tabla Cavidad para la placa de montaje del cable Fig 11 Sujetacable Separe el sujetacable antes de la insta...

Page 8: ...CHADO VerFig 7 Asegúresedequeelcordónde alimentación quede plegado en el resto del área abierta del piso detrás de la gaveta de almacenamiento o gaveta calentadora de la estufa Asegúrese de verificar la nivelación de la estufa o 4B CONEXIONES DEL CORDON DE ALIMENTACION Instrucciones para conexión trifilar para instalaciones existentes SOLAMENTE Consulte la Fig 13 1 Siga las instrucciones de instal...

Reviews: