Section 5 Component Teardown
Section
5
Component
Teardown
5-11
Figure 5-24. Defrost Timer Removal
Screws
Cover
Bolts
Figure 5-25. Filter-Drier Removal
Cut Here
Cut Here
Defrost Timer Removal
The defrost timer is mounted to a bracket which is
secured to the bottom of the base tray with two 1/4”
bolts. (See Figure 5-24)
To remove the defrost timer:
1. Pull unit from its installation position to access the
rear compressor area. Disconnect power from unit.
2. Extract the screws securing the fiber board cover to
the unit frame and remove from unit.
3. Extract the upper screw first securing the defrost
timer cover to the mounting bracket. Remove cover.
4. Extract lower screw. Pull defrost timer from
mounting bracket.
5. Disconnect wire harness connector from defrost
timer.
6. Extract the two bolts with a 1/4” socket or wrench to
remove the mounting bracket to the base tray.
Filter-Drier Removal
The filter-drier is located in the compressor area on the
left side of the compressor. (See Figure 5-25)
To remove the filter-drier:
1. Pull unit from its installation position to access the
rear compressor area. Disconnect power from unit.
2. Extract the screws securing the fiber board cover to
the unit frame and remove from unit.
3. Recover refrigerant by using EPA approved
recovery
system.
4. Using a 3 cornered file, score a groove around
capillary tube as close to old filter-drier as possible.
Break capillary tube along score mark from
filter-drier.
5. Cut condenser outlet tube at filter-drier. Discard
filter-drier.
6. Thoroughly clean condenser outlet tube and
capillary
tube.
7. Place inlet connection of filter-drier over condenser
tube approximately ¼” and solder.
8. Insert capillary tube input end into filter-drier outlet.
Do not allow tube to bottom against screen. Solder
carefully so that solder does not plug capillary tube.
9. Install process tube adapter to filter-drier.
10. Evacuate and charge system using the recom-
mended procedure described under Evacuating and
Recharging in the Refrigeration section.
11. Reassemble unit.
On R-134a systems, the system must NOT be
left open to the atmosphere for more than 10
minutes to prevent moisture contamination of
compressor oil.
CAUTION
Electrical
Connection
All Refrigerator And All Freezer-Pro
Summary of Contents for FPUH17D7KF All Freezer Professional Series
Page 2: ......
Page 20: ...Section 2 Installation Information 2 12 Figure 2 20 Figure 2 21 ...
Page 21: ...Section 2 Installation Information 2 13 Figure 2 22 Figure 2 23 ...
Page 24: ...Section 2 Installation Information 2 16 Notes ...
Page 26: ...Section 3 Electronic Control 3 2 Notes ...
Page 41: ...Section 4 Refrigeration 4 15 HFC 134a CFC 12 Pressure Temperature Chart ...
Page 44: ...Section 4 Refrigeration 4 18 Notes ...
Page 68: ...Section 6 Parts List 6 2 All Refrigerator Cabinet Exploded View And Parts List ...
Page 70: ...Section 6 Parts List 6 4 All Refrigerator Sealed System Exploded View And Parts List ...
Page 72: ...Section 6 Parts List 6 6 All Freezer Door Exploded View And Parts List ...
Page 74: ...Section 6 Parts List 6 8 All Freezer Cabinet Exploded View And Parts List ...
Page 76: ...Section 6 Parts List 6 10 All Freezer Sealed System Exploded View And Parts List ...
Page 78: ...Section 6 Parts List 6 12 Notes ...
Page 82: ...Section 7 Troubleshooting 7 4 Notes ...
Page 83: ...Section 8 Wiring Diagram 8 1 All Refrigerator Wiring Diagram ...
Page 84: ...8 2 Section 8 Wiring Diagram All Freezer Wiring Diagram ...