3. INSTALLATION
WARNING!
Refer to Safety chapters.
3.1 Before the installation
Before you install the hob, write down the
information below from the rating plate. The
rating plate is on the bottom of the hob.
Serial number ...........................
3.2 Built-in hobs
Only use the built-in hobs after you assemble
the hob into correct built-in units and work
surfaces that align to the standards.
3.3 Connection cable
• The hob is supplied with a connection
cable.
• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. Contact an Authorised Service
Centre. The connection cable may only be
replaced by a qualified electrician.
3.4 Assembly
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the
appliances.
min.
50mm
min.
500mm
If the appliance is installed above a drawer,
the hob ventilation can warm up the items
stored in the drawer during the cooking
process.
min.
12
min.
60
min.
28
44
23
min. 55
710
550
520
490
+1
680
+1
max R5
280
60
Find the video tutorial "How to install your
Electrolux Induction Hob - Worktop
installation" by typing out the full name
indicated in the graphic below.
www.youtube.com/electrolux
www.youtube.com/aeg
How to install your Electrolux
Induction Hob - Worktop installation
ENGLISH
25
Summary of Contents for HOB750MF
Page 111: ...111 ...
Page 112: ...867372313 B 142022 electrolux com ...