background image

Drop-In Cooktop / Downdraft Vent 
Countertop Preparation Specifications

For detailed Drop-In Cooktop installation, refer to model-specific product
page and installation guide on web. Plan installation so that all required
minimum clearances between cooktop, overhead cabinets and adjacent
vertical walls are provided.

Position cooktop / vent cutout so all required minimum clearances 
are met. 

Minimum flat countertop area must meet or exceed combined overall
width and depth as shown.

Separate circuits required for cooktop and vent. 

(Refer to 

product-specific electrical specifications.)

Always consult local and /or national electric codes. Check local building
codes for installation requirements, as they may vary per locale.

Downdraft Vent Specifications

For detailed Downdraft Vent installations, refer to model-specific 
product page and installation guide on web.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 1.0 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded 
for safe operation.)

Amps @ 120 Volts = 8.0 Amps

Vent unit outside of building only.

Vent must be installed in vertical orientation only.

1,600 CFM remote exhaust blower (part number 5304444802) 
included with vent – shipped in separate box.

Do not use flexible duct. Round duct instead of rectangular duct
recommended, especially when elbows are required.

When multiple elbows are necessary, ensure a minimum of 24" 
of straight duct between any two elbows.

Thermal breaks such as short section of nonmetallic duct, should 
be used in areas of extreme cold.

For most efficient airflow exhaust, use a straight run or as few elbows 
as possible.

Cold weather installations should have additional backdraft damper
installed.

Installing a Downdraft Vent in combination with any gas cooking surface
will affect optimum burner efficiency.

Note: For planning purposes only. Refer to Product Installation Guide 

on the web at electroluxicon.com for detailed instructions.

Drop-In Cooktop/Downdraft Vent
Countertop Preparation

High standards of quality at Electrolux Home Products, Inc. mean we are 

constantly working to improve our products. We reserve the right to change 

specifications or discontinue models without notice.

USA

250 Bobby Jones Expressway 

Augusta, GA 30907 

1-877-4electrolux (1-877-435-3287) 

electroluxicon.com

CANADA

5855 Terry Fox Way 

Mississauga, ON L5V 3E4 

1-800-265-8352 

electroluxicon.ca

DIC_DDV_PREP  03/08

© 2008 Electrolux Home Products, Inc.

Printed in the U.S.A.

Countertop Preparation for 30" & 36" Drop-In Cooktop / Downdraft Vent Installation

For detailed cooktop and downdraft vent installation specifications, refer to model-specific product page and installation guide on web

2

9

/

16

"

1

/

4

" min.

flat ledge

Backsplash

3

/

4

" max.

  * Overall flat ledge behind

backside of cabinet front

** Minimum flat surface

required to fit top surface
of cooktop and downdraft
vent cap

A

Vertical noncombustible surface - rear wall

25"

B

Top

23

 1

/

4

"

min.

Flush with

back side of

cabinet front

 D*

 E**

C

E30DD75ESS / 30" Cooktop Cutout Dimensions

30" Cooktops

A

B

C

D

E

E30EC65ESS

 30"

27 

1

/

2

"

20 

3

/

8

"

23 

3

/

16

"  24 

3

/

16

"

E30EC70FSS

 30"

27 

1

/

2

"

20 

1

/

4

"

23 

1

/

16

"  24 

1

/

16

"

E30GC64ESS

27 

1

/

2

"

27 

1

/

2

"

19 

7

/

8

"

22 

11

/

16

"  23 

11

/

16

"

E30GC70FSS

28 

1

/

2

"

27 

1

/

2

"

19 

3

/

4

"

22 

9

/

16

"  23 

9

/

16

"

E30IC75FSS

29 

3

/

4

"

27 

1

/

2

"

20 

1

/

2

"

23 

5

/

16

"  24 

5

/

16

"

E36DD75ESS / 36" Cooktop Cutout Dimensions

36" Cooktops

A

B

C

D

E

E36EC65ESS

 36"

33 

3

/

4

"

20 

3

/

8

"

23 

3

/

16

" 24 

3

/

16

"

E36EC70FSS

 36"

33 

3

/

4

"

20 

1

/

2

"

23 

5

/

16

"

24 

5

/

16

"

E36GC65ESS

33 

3

/

4

"

33 

3

/

4

"

19 

7

/

8

"

22 

11

/

16

" 23 

11

/

16

"

E36GC70FSS

34 

1

/

2

"

33 

3

/

4

"

19 

3

/

4

"

22 

9

/

16

" 23 

9

/

16

"

E36IC75FSS

 36"

33 

3

/

4

"

20 

1

/

2

"

23 

5

/

16

" 24 

5

/

16

"

Summary of Contents for ICON Designer E30GC70FSS

Page 1: ... electric and gas codes Refer to Product Installation Guide for detailed installation instructions on the web at electroluxicon com Specifications subject to change 4 Sealed Burners Yes 4 1 17 000 1 16 000 1 9 500 1 5 000 750 Yes Yes 2 Optional Optional Optional Optional 4 1 4 30 21 3 4 Right Rear Included 120V 1 2W 60Hz 15A 0 001 Included Yes Yes 43 Lbs 48 Lbs electroluxicon com 4 Sealed Burner C...

Page 2: ...um clearance when bottom of wood or metal overhead cabinet is protected by not less than 1 8 flame retardant millboard covered with not less than No 28 MGS sheet steel 0 015 stainless steel 0 024 aluminum or 0 020 copper Allow 2 1 2 minimum distance between rear edge of cutout to nearest combustible surface above countertop Allow 7 minimum clearance from edge of cooktop to nearest combustible wall...

Page 3: ...n 2 runners flush with toe plate capable of supporting 200 lbs 24 min 281 2 min 29 max 30 Electric Single Wall Oven Under Counter Installation Specifications Product Weights E30EW75GPS 178 Lbs E30EW75GSS 175 Lbs Single phase 3 or 4 wire cable 120 240 or 120 208 Volt 60 Hertz AC only electrical supply with ground required on separate circuit fused on both sides of line Connected Load kW Rating 240 ...

Page 4: ...ather installations should have additional backdraft damper installed Installing a Downdraft Vent in combination with any gas cooking surface will affect optimum burner efficiency Note For planning purposes only Refer to Product Installation Guide on the web at electroluxicon com for detailed instructions Drop In Cooktop Downdraft Vent Countertop Preparation High standards of quality at Electrolux...