High standards of quality at Electrolux Home Products, Inc.
mean we are constantly working to improve our products.
We reserve the right to change specifications or
discontinue models without notice.
Electrolux Major Appliances, N.A.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-877-4electrolux (1-877-435-3287) • electroluxicon.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-800-265-8352 • electroluxicon.ca
E24RD50QS 07/14
© 2014 Electrolux Home Products, Inc.
Under-Counter Refrigerator Drawers
E24RD50QS
professional series
Front
23
7
/
8
"
Power cord
location (right
bottom rear)
2
3
/
4
" 3
11
/
32
"
Left
26
3
/
8
"
33
3
/
4
"
Adjustable
to 34
3
/
4
"
21
1
/
2
"
39
5
/
32
"
23
23
/
32
"
Drawers fully
extended
Refrigerator Drawers - E24RD50QS
Electrolux ICON
Top
23
7
/
8
"
26
3
/
8
"
24
1
/
8
"
21
3
/
4
"
min.
90°
90°
Recessed
electrical
outlet*
*Proper built-in,
under-counter
installation requires that
both electrical outlet & plug
be completely recessed to ensure
unit will fit flush against rear wall
34"
min.
Under-Counter Refrigerator Drawers Specifications
•
Product Weight – 165 Lbs.
•
Voltage Rating –120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 0.16 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 1.5 Amps
•
Electrical cable supplied.
•
Always consult local and national electric codes.
•
Unit is designed for built-in, under-counter installation only with use of
Anti-Tip Kit and can NOT be used in freestanding installation.
•
Built-in, under-counter installation does not require additional airspace
for top, sides or rear of unit.
•
Proper built-in, under-counter installation requires that both electrical
outlet and plug be completely recessed to ensure unit will fit flush
against rear wall.
•
To allow for ease of installation and removal, it is recommended that
cabinet rough opening dimensions be increased by at least 1/4" over
product’s dimensions.
•
For proper ventilation, unit can NOT be installed behind closed doors; front
grille MUST remain unobstructed.
•
Must be positioned on flat, level surface, capable of supporting entire
weight when fully loaded.
•
Leveling legs supplied to adjust height and level unit.
•
Do not position unit near any heat source to ensure optimum performance.
•
Allow 14" minimum for handle clearance with drawers fully extended.