background image

3

36" GAS RANGE INSTALLATION INSTRUCTIONS

1.

 Model and Serial Number 

Location

The serial plate is located at back of the appliance.
When ordering parts for or making inquires about your 
oven, always be sure to include the model and serial 
numbers and a lot number or letter from the serial plate 
on your oven.

Figure 1

Serial plate 

location

Gas Connector

Important Notes to the Installer

1.  Read all instructions contained in these installation 

instructions before installing range.

2.  Remove all packing material from the oven 

compartments before connecting the electrical supply 
to the range.

3.    Observe all governing codes and ordinances.
4.  Be sure to leave these instructions with the consumer.

5.  Note: For operation at 2000 ft. elevations above see 

level, appliance rating shall be reduced by 4 percent 

for each  additional 1000 ft.

Important Note to the Consumer

Keep these instructions with your owner's guide for future 
reference.

Optional Items Available:

• 

A Stainless Steel Kick Plate

• 

A Black Knob Kit

Those kits can be ordered for purchase through an 
Electrolux Service Center at 1-877-4ELECTROLUX (1-877-
435-3287).

Preferred Method

Grounding type

wall receptacle

Do not, under any 

circumstances, cut, 

remove, or bypass 

the grounding 

prong.

Power supply cord with 

3-prong grounding plug.

Figure 2

2.

 Electrical Requirements

120 volt, 60 Hertz, properly grounded dedicated circuit 
protected by a 15 amp circuit breaker or time delay fuse. 

Note: 

This range is not recommended to be installed 

with a Ground Fault Interrupt (GFI).

Do not use an extension cord with this range.

Grounding Instructions

IMPORTANT

 Please read carefully.

For personal safety, this appliance must be properly 
grounded.

The power cord of this appliance is equipped with a 
3-prong (grounding) plug which mates with a standard 
3-prong grounding wall receptacle (see Figure 2) to 
minimize the possibility of electric shock hazard from the 
appliance.
The wall receptacle and circuit should be checked by 
a qualified electrician to make sure the receptacle is 
properly grounded.
Where a standard 2-prong wall receptacle is installed, 
it is the personal responsibility and obligation of the 
consumer to have it replaced by a properly grounded 
3-prong wall receptacle.

Do not, under any circumstances, cut or remove the 
third (ground) prong from the power cord.

 

Disconnect electrical supply cord from 

wall receptacle before servicing range.

 Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not use the gas supply line for grounding 

the appliance.

Failure to do any of the above could result in a 

fire, personal injury or electrical shock.

Summary of Contents for ICON Professional E36GF76JPS

Page 1: ...TRUCTIONS FOR FUTURE REFERENCE OBSERVE ALL GOVERNING CODES AND ORDINANCES Note For appliances installed in the state of Massachusetts see page 2 Refer to your serial plate for applicable agency certification NOTE 28 71 1 cm minimum clearance between the cooktop and the bottom of the cabinet when the bottom of wood or metal cabinet is protected by not less than 1 4 0 64 cm flame retardant millboard...

Page 2: ...nattended Stepping leaning or sitting on the door of this range can result in serious injuries and can also cause damage to the range Do not store items of interest to children in the cabinets above the range Children could be seriously burned climbing on the range to reach items To eliminate the need to reach over the surface units cabinet storage space above the units should be avoided Adjust su...

Page 3: ...ove or bypass the grounding prong Power supply cord with 3 prong grounding plug Figure 2 2 Electrical Requirements 120 volt 60 Hertz properly grounded dedicated circuit protected by a 15 amp circuit breaker or time delay fuse Note This range is not recommended to be installed with a Ground Fault Interrupt GFI Do not use an extension cord with this range Grounding Instructions IMPORTANT Please read...

Page 4: ...valve in the gas supply line Wait a few minutes for gas to move through the gas line The gas supply between the shutoff valve and the regulator may be connected by rigid piping or by A G A C G A approved flexible metallic union connected piping where local codes permit use The gas supply piping can be through the side wall of the right cabinet The right side cabinet is an ideal location for the ma...

Page 5: ... off the manual gas shut off valve Make sure the range is cold Open the oven door Lift the range at the front and slide it out of the cut out opening without creating undue strain on the flexible gas conduit Make sure not to pinch the flexible gas conduit at the back of the range when replacing the unit into the cut out opening Close the door and switch on the electrical power and gas to the range...

Page 6: ...normal operation after air has been purged from supply lines Visually check that burner has lit c Once the burner lights the control knob should be rotated out of the LITE position There are separate ignition devices for each burner Try each knob separately until all burner valves have been checked Regular Burner Burner Cap Fixed Burner Ring and Burner Base Dual Surface Burner Burner Base Fixed Bu...

Page 7: ...igure 8 4 Adjust the LOW Setting of Regular Burner see figure 7 on the Surface Burner Valves Figure 8 a Push in and turn control to LITE until burner ignites b Quickly turn knob to LOWEST POSITION c If burner goes out reset control to OFF d Remove the surface burner control knob and decorative ring e Insert a thin bladed screwdriver into the hollow valve stem and engage the slotted screw inside Fl...

Page 8: ...nt Safety Warning To reduce the risk of tipping of the range the range must be secured to the floor by the properly installed anti tip bracket and screws packed with the range These parts are located in a plastic bag in the oven This gas range has two brackets Failure to install the bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it ...

Page 9: ...la agencia de servicio o el proveedor de gas Nota Para electrodomésticos instalados en el estado de Massachusetts Vea página 12 P N 318201779 1006 Rev A English pages 1 8 Español páginas 9 16 Notas páginas 17 19 Diagrama de la instalación alámbrica página 20 G F 13 Max 33 cm Max 35 7 8 Mín 91 1 cm Mín PARED PARED 18 Mín 45 7 cm Mín A B C D E NOTA Un espacio mínimo de 28 71 1 cm entre la superficie...

Page 10: ... Mobil Home Construction and Safety título 24 HUD parte 280 o cuando tal estándar no se aplica el Standard for Manufactured Home Installation 1982 Manufactured Home sites Communities and Setups ANSI Z225 1 NFPA 501A edición más reciente o con los códigos locales Esta estufa ha sido diseñada y certificada por el organismo CSA Internacional Como en cualquier electrodoméstico donde se use gas y se ge...

Page 11: ...nchufe de pared con toma de tierra Figura 2 2 Requisitos eléctricos 120 voltio 60 Hertzio circuito dedicado apropiadamente puestos a tierra protegido por un circuito de amperio o fusible de demora de tiempo de 15 amp Nota no es recomendado instalarlo con un Interruptor GFI de puesta a tierra No utilice una extensión con esta estufa Instrucciones de puesta a tierra IMPORTANTE Por favor lea con cuid...

Page 12: ...a la válvula de cierre La válvula abre o cierra es para abrir o cerrar el suministro de gas al aparato Abra la válvula de cierre en la línea de suministro de gas Espere unos minutos a que el gas pase por el tubo El suministro de gas entre la válvula de cierre y el regulador se puede conectar con tubería rígida o con tubería flexible unión metálica conectada y aprobada por la AGA CGA donde los códi...

Page 13: ...cela fuera de la abertura sin crear tensión desmedida sobre el conducto flexible de gas Ase gúrese de no pellizcar el conducto flexible de gas detrás de la estufa al reinstalar la unidad en la abertura Cierre la puerta y abra el gas y la corriente eléctrica a la estufa 6 Estufa Colocación Para eliminar el riesgo de quemaduras o fuego por el contacto de superficies sobrecalentadas cualquier espacio...

Page 14: ... c Luego que el quemador se haya encendido la perilla debe ser girada fuera de la posición LITE Cada quemador tiene su encendedor individual Controle las perillas separadamente hasta que todas las válvulas hayan sido controladas 7 Instalación de la estufa 1 La parte trasera de la estufa puede ser directamente instalada a ras con la pared trasera de la estructura 2 Para reducir posibles marcas o ra...

Page 15: ... ajustar individualmente a Presione y gire el control a la posición LITE hasta que la porción posterior del quemador puente se encienda b Gire rápidamente a la perilla a la POSICIÓN MÁS BAJA c Si el quemador se apaga reajuste el control a OFF d Retire la perilla del quemador de superficie e El tamaño de la flama de la porción posterior del que mador puente puede aumentarse o disminuirse dándo le v...

Page 16: ...do este instalada utilice el diagrama en el cuadro 10 para situar el soporte si la plantilla no está disponible 4 Marque en el piso la localización de los agujeros de montaje demostrados en la plantilla posición derecha y izquierda Para una instalación más fácil los agujeros 1 2 1 3 centímetros de diámetro y 3 16 4 8 milímetros de profundidad pueden perforarse en el piso 5 Quite la plantilla y col...

Page 17: ...17 NOTES NOTAS ...

Page 18: ...18 NOTES NOTAS ...

Page 19: ...19 NOTES NOTAS ...

Page 20: ...Wiring Diagram diagrama de la instalación alámbrica 20 ...

Reviews: