9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar
11,65 kW
Gas replace‐
ment:
G30 (3+) 28-30 mbar
825 g/h
G31 (3+) 37 mbar
811 g/h
Electric sup‐
ply:
220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp car‐
tridge fuse
Appliance cat‐
egory:
II2H3+
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Multi Crown
4,0
1,4
146
Rapid
2,95
0,75
119°
Semi-rapid
1,85
0,6
92
Auxiliary
1,0
0,33
70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Multi Crown 3,55
1,4
095
258
254
Rapid
2.8
0,95
86
204
200
Semi-rapid 2,0
0,6
71
145
143
Auxiliary
1,0
0,33
50
73
71
10. ENERGY EFFICIENCY
10.1 Product Information according to UK Ecodesign Regulation
Model identification
KGS9536X
Type of hob
Built-in hob
ENGLISH
19