SOI/DT 2006-01 dmm
66/71
599 37 47-13
6.4
Access from the bottom of the appliance
6.4.1 Damper
a. Press the locking key and at the same time remove the
pin using pliers.
b. Remove the damper from the support.
When re-assembling:
Ö
Check that the pin is not damaged; if so, replace it.
Ö
Check that the anchor tabs protrude correctly.
6.4.2 Filter body tub hose + Pressure chamber
c. Loosen the clamps and detach the pressure switch tubes from
the pressure chamber.
d. Remove the fixing screw.
e. Use pliers to widen the spring clip and detach the pressure
chamber from the tub hose.
When re-assembling
: Check that the pressure chamber is
clean and secure the tubes and clips firmly in their original
positions
6.4.3 Drain
pump
f. Detach the connectors.
g. Press down the anchor tab.
h. Turn the pump counter-clockwise.
i. Remove
the
pump.
6.4.4 Inverter
j. Push the hook which fits the inverter to the lower crosspiece.
k. Lift it up and remove.
l. Detach the connectors.
g
h
d
a
b
a
b
j
k