Data di emissione:
February, 2019
Revisione:
2
Pag. :
7/24
!Caution!
T
o avoid electrical shock or contact with
moving parts, before proceeding with the
disassembling operations, make sure all
switches are in “OFF” position and that the
main power supply is disconnected.
-
S
witch off the machine and disconnect the
power cable.
-
R
emove the cover.
-
W
ash and sanitize your hands and forearms.
-
S
imultaneously press the two securing tabs
and lift the tap to extract it from its seat (see
fig.4).
-
D
isassemble the tap by keeping the body
pressed down and slipping the lever from its
seat (fig.5).
!Caution!
T
o prevent bacteria growth, remove all
O-rings when cleaning.
F
ailure to do so could create a health
hazard.
-
P
ull the tank upward and outward, as shown,
to completely remove it from its seat (fig.6).
Fig. 4
Fig. 5
Fig. 6