2
Please keep both cover flaps open and cross reference pictures
with text where necessary.
Before you start, please refer to the electrical safety supply
instructions on page 63 (U.K. and Ireland only).
Clean air for healthier homes
Now that you have an Electrolux Oxy
3
silence Air Cleaner, you
will be breathing cleaner air. Obviously, you should locate this in
a room where you spend most time e.g. living room or bedroom.
Wherever there are people, plants or pets, there are airborne
particles that can affect your wellbeing, especially if you suffer
from allergies. For instance, did you know that the air inside a
room could be more polluted than the air in a large city? Scien-
tific studies have shown the following levels of particles per litre
of air:
Usually, you cannot see or smell particles in indoor air. But they
are there, and they can affect your health. If used in rooms of
the recommended size, your air cleaner reduces particle content
by at least 80% continuously. It reduces airborne particles in
a room, such as dust, pollen, spores, particles from animal fur
and industrial pollutants which improves the air quality. It will
also reduce the amount of bacteria and viruses.
Filtration in several stages
To guarantee the highest quality of air, the air cleaner has a
unique multi-stage electrostatic filtration system.
Stage 1
Two pre-filters remove large particles such as strands
of hair.
Stage 2
An electrostatic main filter reduces smaller airborne
particles. (See above)
Stage 3
Using a carbon filter* will also reduce gases and
odours in the indoor air. A carbon filter will reduce the air flow
somewhat. Remove the protective plastic, put the carbon filter
in place inside the air cleaner above the main filter and replace
the cover. The carbon filter is available as an accessory
(reference no. EF103) and can be used in all models.
For your safety
The Air cleaner is an electrical appliance and should be treated
accordingly. Follow these safety instructions and retain this
booklet for reference.
• The cleaner is only to be used by adults. Young children or
infirm persons should be supervised to ensure that they do not
play with the appliance.
• Do not use in humid places such as bathrooms. If liquid enters
the air cleaner, turn it off and have it inspected by an autho-
rised service station.
• Do not use outdoors.
• Do not use near flammable gases.
• Do not locate under a smoke alarm.
• Do not use if the lead or plug are damaged. To prevent
hazards, a damaged lead or plug must always be replaced
at an authorised Electrolux service station.
• Do not put objects on top of or inside the unit.
• Do not block the grills.
• Always disconnect from the power supply before removing the
filters for cleaning.
• Do not wash the main filter in salt water or dishwasher.
• Always change a damaged main filter.
Like other electrical appliances, the air cleaner may generate a
small amount of ozone. You might detect a faint smell (similar to
chlorine) especially when the unit is new. However, the amount
generated is extremely small and well below the limits stipulated
by the authorities. To reduce the amount of ozone you can fit
your Air cleaner with a carbon filter.
For best results
Place the air cleaner on the floor next to a wall. The Air cleaner
sucks in air at floor level and blows it out at the top. If there is a
wall mounted heater, place the air cleaner along the same wall
so that the rising warm air coincides with the air flow of the
cleaner. When using two or more units in one room, place them
along the same wall, as far apart as possible.
COUNTRYSIDE
1 million
CITY
100 million
IN THE HOME
100 million
HIGHWAY
1 billion
TOBACCO SMOKE
100 billion
Operating Instructions
1.
Regulators*
10.
Carrying handle
2.
Buttons*
11.
Power cord
3.
Sound Sensor*
12.
Compartment for unused cord
4.
Reset button*
13.
Top cover release button
5.
Programme button*
14.
Rating plate
6.
Childproof lock button*
15.
Indicator lamp*
7.
Air inlet grills
16.
Reserve wire/corona wire
8.
Air outlet grills
17.
Ionization chamber
9.
Pre-filter door
18.
Remote control*
*Only on certain models
Usage
All models are intended for continuous use at fan speed
setting 1 or any one of the automatic programmes*. The fan
speed setting can be changed to 2 or 3 if necessary.
The best results are achieved by leaving the air cleaner on
around the clock. (It uses less power than most light bulbs.)
Buttons
Controls the active programme. Press the button to
switch between and
manual mode.
Changes fan speed setting manually. Press the button
to switch between the different fan speeds.
Turns the air cleaner on and off.
Clean air delivery rate*)
(CADR +/-10% m
3
/h)
Position 1
130
110
Position 2
240
230
Position 3
380
380
Room size capacity (m
3
)
Position 1
27
23
Position 2
50
48
Position 3
79
79
Noise level (dBA)
(ISO 3741)
Position 1
31
28
Position 2
44
43
Position 3
63
63
Power consumption (W)
Position 1
30
30
Position 2
35
35
Position 3
70
60
*) = CADR measured without carbon filter.
Meets the safety requirements and ozone emission limits of
the IEC 60335-1 and 60335-2-65 directives. CE-certified.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
English
Technical Specifications
220-240V/50-60HZ 100-110V/50-60Hz
Summary of Contents for oxy3 silence
Page 1: ......
Page 2: ......
Page 3: ...1 2 3 4 5 6 7 8 9 10 12 11 13 14 18 17 15 16 15 ...
Page 4: ......
Page 5: ......
Page 6: ...a b c d f h g i j k e ...
Page 7: ......
Page 8: ...The Electrolux Group The world s No 1 choice 822 86 29 01 ...
Page 32: ...24 ...
Page 33: ...25 ...
Page 36: ...28 ...
Page 37: ...29 ...
Page 40: ...32 ...
Page 41: ...33 ...
Page 42: ...34 ...
Page 43: ...35 ...
Page 44: ...36 ...
Page 45: ...37 ...
Page 48: ...40 ...
Page 49: ...41 ...
Page 50: ...42 ...
Page 51: ...43 ...
Page 54: ...46 ...
Page 55: ...47 ...
Page 56: ...48 ...
Page 57: ...49 ...
Page 63: ...55 ...
Page 65: ...57 ...
Page 68: ...60 ...
Page 69: ...61 ...
Page 71: ...63 ...
Page 74: ...66 ...
Page 75: ...67 ...
Page 76: ...68 ...
Page 78: ...70 ...
Page 79: ......
Page 80: ......