8
electrolux
installation manual
90° elbow
pipe
90° sweep elbow
90° sweep T
pipe connector
45° single Y
90° sweep elbow
90° elbow
Example showing piping with different types of
connections.
45° elbow
90° sweep T
45° elbow
VacPan Installation
VacPan is most useful in the kitchen, in the hallway, etc. It can be easily installed, for
example, in a cabinet footing or next to the wall.
7 1/2”
(190 mm)
VacPan dimensions:
8 5/8”
(215 mm)
1 9/16” (40 mm)
2 1/4” (53 mm)
low voltage
connections
switch
2 3/4”
(70 mm)
2 3/4”
(70 mm) 4”
(99 mm)
Notes!
Minimize Condensation
If the tubing installation is carried out in winter, a large amount of condensation may be generated. To reduce the amount of condensation, close all pipe holes and inlet open-
ings using duct tape during installation. Before starting to use the central vacuum system for the first time, let the system vacuum and circulate fresh air for a few minutes, and
make sure that there is no water in the dust container. If there is water in the container, drain it and continue vacuuming until no more water is accumulated.
6 1/2”
(165 mm)
DO NOT
GLUE
90° elbow
front edge is flush
with floor surface
central vacuum
starts when
switch is
activated
additonal
cover plate is
available
90° sweep
elbow
floor
floor
wall
90° elbow
maintenance access
required
Example of a VacPan
installed in a cabinet.
VacPan
installation using flexible
vacuum tube
min. 4” (100 mm)
piping may exit
the cabinet and go
vertical
cabinet floor
wall
floor