10
The minimum distance combustible material can be fit-
ted above the hob in line with the edges of the hob is
420 mm. If it is fitted below 420 mm a space of 55 mm
must be allowed from the edges of the hob.
The minimum distance combustible material can be fit-
ted directly above the hob is 700 mm.
This appliance conforms to Type Y (IEC 335-2-6)
with regard to fire protection. Only appliances of
this type may be installed on one side of adjacent
cabinets or walls.
Installation
S
Cut the worktop according to the prescribed dimen-
sions. See fig. 1. Saw exactly along the scribed line.
S
Fix according to fig. 2.
Fastening according to fig. 3
S
Tighten bracket against the underside of the work-
top. Fix according to fig. 2.
S
Using a screwdriver, tighten the tension clamps
evenly starting at the centre and moving diagonally
until the built-in rim is tight on the worktop.
S
Do not over tighten.
S
Do not use an electric or pneumatic screwdriver
without an adjustable safety clutch.
Points for fixing clamps
fig 1
fig 2
fig 3
hobs frame Ceramic glass plate
worktop
fixing clamp
Einbaukasten
R5
radius
R5