Doc. No.:
560001 EG
Page:36
Ed.1" 08-2014
From ser. no.:
ENGLISH
8.2 Table of alarms and signals: functions enabled/disabled
The following table highlights the functions that are enabled and disabled in the various alarm situations.
Code
PD valve
Compressor
Defrost
Evap. fans
Cond. fans
Continuous cycle
rE
Duty setting (c4)
Duty setting (c4)
unchanged
unchanged
unchanged
unchanged
E0
Duty setting (c4)
Duty setting (c4)
unchanged
unchanged
unchanged
unchanged
E1
unchanged
unchanged
unchanged
unchanged
unchanged
unchanged
E2
unchanged
unchanged
unchanged
unchanged
unchanged unchanged
E3
unchanged
unchanged
unchanged
unchanged
unchanged
unchanged
E4
unchanged
unchanged
unchanged
unchanged
unchanged unchanged
‘___’
unchanged
unchanged
unchanged
unchanged
unchanged unchanged
LO
unchanged
unchanged
unchanged
unchanged
unchanged unchanged
HI
unchanged
unchanged
unchanged
unchanged
unchanged
unchanged
AFr
off off
unchanged
unchanged
unchanged
unchanged
IA
Duty Setting (A6)
Duty setting (A6)
unchanged
unchanged
unchanged
unchanged
dA
Duty setting (A6) if A7<>0
Duty setting (A6) if A7<>0
unchanged
unchanged
unchanged
unchanged
dEF
unchanged
unchanged
unchanged
unchanged unchanged unchanged
Ed1
unchanged
unchanged
unchanged
unchanged unchanged unchanged
Ed2
unchanged
unchanged
unchanged
unchanged unchanged unchanged
Pd
unchanged
unchanged
unchanged
unchanged unchanged unchanged
LP
off off
unchanged
unchanged
unchanged
unchanged
Ats
unchanged
unchanged
unchanged
unchanged unchanged unchanged
cht
unchanged
unchanged
unchanged
unchanged unchanged unchanged
CHt
unchanged
off off
unchanged
unchanged
unchanged
dor
unchanged
unchanged
unchanged
unchanged unchanged unchanged
Etc
unchanged
unchanged
unchanged
unchanged unchanged unchanged
EE
off
off
not performed
off
off
not performed
EF
off
off
not performed
off
off
not performed
HA
unchanged
unchanged
unchanged
unchanged unchanged
unchanged
HF
unchanged
unchanged
unchanged
unchanged unchanged
unchanged
n1-n6
unchanged unchanged
unchanged
unchanged
unchanged
unchanged
dnL
unchanged unchanged
unchanged
unchanged
unchanged
unchanged
d1 - d6
unchanged
unchanged
unchanged
unchanged
unchanged
unchanged
Tab. 8.b
Code
AUX dead zone
AUX light anti-sweat
AUX auxiliary anti sweat
AUX second step
rE
off
off
off
Duty setting (C4)
E0
off
off
off
Duty setting (C4)
E1
unchanged
unchanged
unchanged
unchanged
E2
unchanged
unchanged
unchanged
unchanged
E3
unchanged
unchanged
unchanged
unchanged
E4
unchanged
unchanged unchanged
unchanged
‘___’
unchanged
unchanged
unchanged
unchanged
LO
unchanged
unchanged
unchanged
unchanged
HI
unchanged
off off
unchanged
AFr
unchanged
unchanged
unchanged
off
IA
off
off
off
Duty setting (A6)
dA
off if A7<>0
off if A7<>0
off if A7<>0
Duty setting (A6) if A7<>0
dEF
unchanged
unchanged
unchanged unchanged
Ed1
unchanged
unchanged
unchanged unchanged
Ed2
unchanged
unchanged
unchanged unchanged
Pd
unchanged
unchanged
unchanged unchanged
LP
unchanged
unchanged
unchanged off
Ats
unchanged
unchanged
unchanged
unchanged
cht
unchanged
unchanged
unchanged
unchanged
CHt
unchanged
off off
off
dor
unchanged
unchanged
unchanged unchanged
unchanged
unchanged
unchanged
unchanged
EE
off off
off
off
EF
off off
off
off
HA
unchanged
unchanged
unchanged
unchanged
HF
unchanged
unchanged
unchanged
unchanged
n1 - n6
unchanged
unchanged
unchanged
unchanged
dnL
unchanged
unchanged
unchanged
unchanged
d1 - d6
unchanged
unchanged
unchanged
unchanged
tab. 8.c