19
Maintenance
Maintenance
Daily
• Clean the door seal from detergent residue.
• Make sure the door is not leaking.
• Clean the detergent supply box and wipe off the machine with a damp
rag.
• Make sure the drain valve is not leaking.
• Start the machine and make sure the door is locked during the program.
Rapid advance the program to stop and make sure the door cannot be
opened until after the program is complete.
Every month
• Check that valves, hoses and connections are not leaking.
• Remove any lint from the drain connection, joints in the drain pipe, etc.
Every third month
When chemicals have collected on the edges of the panels:
• Turn off power to machine.
• Turn off the water supply and release the pressure from the inlet hoses.
• Remove the water inlet hoses from the back of the machine and clean
or change the inlet filter.
• Clean the detergent supply box thoroughly.
• Take off the top and front machine panels.
• Wash away detergent and other chemicals from the panels to stop them
rusting.
• Make sure there are no leaks inside the machine. Repair as necessary.
• Clean the seal around the door.
• Refit the top and front panels.
• Deliming. Use a program with high temperature and add a deliming
agent, e.g. citric acid.