Installation
25
Gas group
Injector size
Ø mm (1)
Air reducing
plate (fig. 5)
Inlet pres-
sure (mbar)
Injector
pressure
(mbar)
Label no.
(fig. 10 )
I2H, I2E(LL)
3.8
Ø38
20
10.5
DEFAULT
I2E+
3.3
Ø38
20/25
20/25
487266723
I2L (LL)
3.8
Ø38
20/25
15, 2
487266723
I3B/P, I3+
2.3
NONE
30, 28/37
30, 28/37
487266721
I3B/P (37)
2.1
NONE
37
37
487266722
I3B/P (50)
2.3
NONE
50
30
487266722
Gas installation - table of pressure and adjustment
This gas appliance has been build to run on natural gas group I2H and I2E(LL), commonly
identified by GNH.
The data label shows the injector size and the injector pressure and the countries that use this
gas quality: DK, NO, SE, FI, CH, CZ, EE, LT, SL, TR, BG, RO, GB, ES, GR, IE, IT, PT, AT, LV,
HU, IS, SK, DE, PL, LU and non-European countries.
Before connecting the appliance please make sure that the supplied gas type is correct.
Following gas conversions are possible:
1.
Appliances to be installed to run on GNH or GNL in FR, BE: I2E+
2.
Appliances to be installed in NL, parts of DE and Non-European contries: I2L.
3.
Appliances to be installed to run on LPG in: DK, NO, SE, FI, EE, LT, SL, TR, DE, NL,
CH, CZ, HU, GR, MT, CY, LV, SK, LU, BG and Non-European contries: I3B/P .
4.
Appliances to be installed to run on LPG in: GB, ES, GR, IE, IT, PT, CH, CZ, BE, FR,
CY, EE, LV, LT, LU, RO: I3+ .
5.
Appliances to be installed to run on LPG in: AT: I3B/P (50 mbar) inlet pressure.
6.
Appliances to be installed to run on LPG in: PL: I3B/P (36 mbar) inlet pressure.
Fig. 1 - T4290 only
Gas group
Injector size
Ø mm (1)
Air reducing
plate (fig. 7)
Inlet pres-
sure (mbar)
Injector
pressure
(mbar)
Label no.
(fig 10)
I2H, I2E(LL)
5.6
Ø40
20
8
DEFAULT
I2E+
4.7
Ø40
20/25
20/25
487266733
I2L (LL)
6.2
Ø40
20,25
8
487266733
I3B/P, I3+
3.2
Ø40
30, 28/37
30, 28/37
487266731
I3B/P (37)
3.05
Ø40
37
37
487266732
I3B/P (50)
3.2
Ø40
50
30
487266732
Fig. 2 - T4530 only