53
Tango 0060 5-2021
Screen Messages:
“No Communication – Touch to proceed”
ICU board unplugged
New ICU board has no software installed, try loading software
Replace ICU
Left Milk Level Add Milk
ST/Ave: 2 gray jumper loops on CN1 bypass future milk level sensor
UNO/Solo: 3 gray wires on CN1 must be jumped together (are inside sleeve)
Brew group temperature reads ~-630F
Temperature probe disconnected on rear of Turntable
Code 1 – No reading from Steam boiler filling probe during normal operation
Located in center top of steam boiler
Restricted water flow to machine
Filling Valve blocked
Valve driver board unplugged
Code 2 – Steam boiler filling timeout on startup (Pumps runs)
Restricted water flow to machine
Filling Valve blocked
Valve driver board unplugged
Code 3 – No reading from Steam boiler low level safety probe during normal operation
Located on left top of steam boiler
Restricted water flow to machine
Filling Valve blocked
Valve driver board unplugged
Code 4 – Turntable rotation timeout message
Waste drawer removed during drink cycle or cleaning or drawer not fully seated
TT Turntable bearing setting too tight (above 210)
Loose wire on either turntable position sensor (or sensor unplugged)
Blown fuse F4, Primary of the transformer
High AMP draw from piston or turntable motor
Service Piston or Turntable if dirty
Troubleshooting