11.5
Cleaning the control panel
and housing
Use a standard neutral soap detergent to
clean the control panel and housing.
Use a moist cloth to clean. Dry the
cleaned surfaces with a soft cloth.
CAUTION!
Do not use furniture cleaning
agents or cleaning agents
which can cause corrosion to
clean the appliance.
11.6
Cleaning the airflow slots
Use a vacuum cleaner to remove the fluff
from the airflow slots.
12.
TROUBLESHOOTING
Problem
1)
Possible cause
Remedy
The tumble dry-
er does not op-
erate.
The tumble dryer is not connec-
ted to mains supply.
Connect in at mains socket.
Check fuse in fuse box (domestic
installation).
The loading door is opened.
Close the loading door.
The On/Off (Ein/Aus) button was
not pushed.
Push the On/Off (Ein/Aus) button.
The Start/Pause button was not
pushed.
Push the Start/Pause button.
The appliance is in the standby
mode.
Push the On/Off (Ein/Aus) button.
Unsatisfactory
drying result.
Incorrect programme selection.
Do the selection of the applicable
programme.
2)
The filter is clogged.
Clean the filter.
3)
The Dry Plus () option
was in minimum level.
4)
Change the Dry Plus ()
option to the moderate or maxi-
mum level.
4)
Too high volume of the load.
Obey the maximum load volume.
The airflow grill is clogged.
Clean the airflow grill in the bot-
tom of the appliance.
Dirt on the humidity sensor in the
drum.
Clean the front surface of the
drum.
Incorrect remaining laundry mois-
ture degree.
Adjust remaining laundry moisture
degree.
5)
The heat exchanger is clogged.
Clean the heat exchanger.
3)
ENGLISH
21