background image

FTW4

1EN

Technical characteristics - TW1E

Speed

Variable speed

m/min

7-14

Capacity

Variable capacity

Trays/h

600-1200

Feeding motor

kW

0,25

Washing section

Temperature

°C 55-65

Tank capacity

l

114

Pump capacity

l/min

700

Pump power

kW

2,55

Tank heating elements

kW

9

Rinsing section

Final rinse

l/h

200

Temperature

°C

85

Boiler heating elements

kW

12

Drying tunnel

Temperature

°C

30-40

Quality of circulated air

m

3

/h

195

Fan motor

kW

3

Total power

kW

27,2

Condensing unit

Steam cooling area

m

2

10,5

Water consumption (1)

l/h

300

Air emission

m

3

/h

450

Air temperature (2)

°C

25-35 approx.

Humidity

%

75-85

Fan motor

kW

0,11

Energy savings

Condensing unit

kW/h

12

Dimensions

Lenght with dryer (3)

mm

2900

Height/open door

mm

1905/2050

Width

mm

824

Working height

mm

900

Feet

mm

200

Water supply

Temperature "operation"

°C

10-15

Temperature "tank filling"

°C

50

Hardness maximun

°dH

5

Pressure

Bar

3-9

STEAM HEATED MACHINES

Total power

With dryer

kW

6,2

Steam pressure

bar

0,5-3,0

Steam consumption

kg/h

34

(1) Water for final rinse is in this volume
(2) Cold water temperature 10°C
(3) Including the hood to install on unloading section for noise reduction

Electrolux Food Service Equipment

www.electrolux-professional.com

TW1E

A= Hot water inlet
B= Colt water inlet
C= Drain
F= Steam inlet
G= Condensation outlet
P= Fumes outlet
Q= Equipotential screw

tray washer/eng  22-02-2005  12:17  Pagina 1