12
Operation
Controls
Dead-front mode
Stand-by mode
In dead-front mode, press any key for enter in stand-
by mode.
If the hood is in stand-by mode, after 10 seconds on
return automatically in dead-front mode.
Light switch
Press any key for enter in stand-by mode.
Push the light switch once to turn the lights ON to a
dim level.
Push a second time to turn the lights ON to a brighter
level.
Push a third time to turn the lights OFF (stand-by
mode).
Fan speed switches
Press any key for enter in stand-by mode.
The fan speed switches turns the fan on.
1 : fan ON at low speed
2 : fan ON at medium-low speed
3 : fan ON at medium-high speed
4 : fan ON at high speed
Fan on/off switch
Push this fan switch to turn OFF the fan.
The hood turns in the stand-by mode.
Delay shut off switch
Pressing this switch when is active any speed, sets a
timer which keeps the fan operating at this speed for
10 minutes (the number “10” appears in the display).
After 10 minutes, the hood turns in the stand-by mode.
Heat Sentry active
Push this switch once to turn the timer Off.
Filter reset switch
When the filter switch is illuminated, it is necessary to
clean the GREASE FILTERS. Once the grease filters
are cleaned and installed, press in and hold the “filter
reset switch” for approximately 3 seconds.
When the filter switch is illuminated and blink, it is
necessary to replace the CHARCOAL FILTER. Once
the new charcoal filter is installed, press in and hold
the “filter reset switch” for approximately 3 seconds.
Heat Sentry
Your hood is equipped with a HEAT SENTRY™
thermostat. This thermostat is a device that will turn
on or speed up the blower if it senses excessive heat
above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns
blower up to HIGH speed.
When the Heat Sentry is active, the word “HS” appears
in the display and the tone alarm is active. To disarm
the tone alarm, press the 4 fan speed switch.
When the temperature level drops to normal, the blower
will return to its original setting.
light
switch
fan speed
switches
delay
shut
off
display
filter
reset
switch
fan
on/off
switches
IMPORTANT
The HEAT SENTRY thermostat can start the
blower even if the hood is turned OFF. When
this occurs, it is impossible to turn the blower
OFF with its switch. If you must stop the blower,
do it from the integral disconnecting switch
located inside the blower housing.