47
Program unit
MAX FILL TIME, SEC.
Specify with the knob the maximum time (in seconds, 0 - 2550)
it should take to fill the machine with water to the programmed
level.
If the water has not reached the correct level within the set time,
the ”NO WATER” error message will appear on the display.
6. WATER IN DRUM
Select if the error code shall be active or not. For an explanation
of the error code, see section "Error codes".
7. DRUM OVERFILLED
Select if the error code shall be active or not. For an explanation
of the error code, see section "Error codes".
10. DRUM NOT DRAINED
Select if the error code shall be active or not. For an explanation
of the error code, see section "Error codes".
MACHINE ADDRESS
Specify with the knob the machine’s address (1 - 127) that is used
when the machine is connected to the CMIS, TMIS or ELS Net
-
work System.
Default value is set to 0, inactive.
PASSWORD
Select whether the functions under CONFIG 1 should be pass-
word protected or not.
The password comprises four numerals. The code 0000 means
no password is required for the CONFIG 1 menu.
The password code can be changed or removed at any time.