SOI/DT 2005-01 dmm
599 36 82-56
22/65
8.5 Synthetics programmes: cold – 30 – 40 – 50 – 60° (without options)
Motor Movement
CYCLE
N.° PHASE
Description
Drain
pump
Recirc.
Pump
Deterg.
Disp
Rpm
Movem.
Pause
60 50 40 30 *
1 Calibration
Level
ON
OFF
NO
mov
Drain
2
Flow calibration
Level
OFF
OFF
PW
NO mov
Water fill
3
Maintenance water softener
Time
OFF
OFF
PW
55
4
12
1 min.
4
Water fill
Level
OFF
OFF
PW
NO mov
COT_FIRST_PW_LEV
5
Maintenance & Refill
Time
OFF
ON (35/15)
PW
55
4
12
4 min.
COT_FIRST_PW_LEV
6
Heating
Temperature
OFF
ON (35/15)
PW
55
4
12
Heating up to 30°
20°
7
Maintenance
Time
OFF
ON (35/15)
PW
55
4
12
4 min.
8
Drain
Time
ON
OFF
NO mov
Empty Elect.+ 14 sec.
9
PREWASH
Spin
Time
ON
OFF
IMP C0
4,5 min. with AS control
10 Calibration
Level
ON
OFF
NO
mov
Drain
11
Flow calibration
Level
OFF
OFF
PW
NO mov
Water fill
12
Maintenance water softener
Time
OFF
OFF
PW
55
4
15
1 min.
13
Water fill
Level
OFF
OFF
W
NO mov
SYN_FIRST_W_LEV
14
Maintenance & Refill
Time
OFF
ON (35/15)
W
55
8
8
3 min.
SYN_SECOND_NW_LEV
15
Heating
Temperature OFF ON
(35/15) W 55 10 3 40° 40° 40° 30° 20°
16 Heating
Temperature
OFF
ON
(35/15)
W
55
8
8
60°
50°
17
Maintenance
Time
OFF
ON (35/15)
W
55
10
3
10 min. 10 min. 10 min. 10 min.
T° ref
10 min.
18
Heating
Time
OFF ON
(35/15) W 55 10 3 60° 50° 40° 30°
19
Maintenance
Time
OFF
OFF
W
55
10
3
15 min. 15 min. 15 min. 15 min.
20
Maintenance
Time OFF
ON
(35/15)
W
55
10
3
15
min.
21 Cooling
Time
OFF
OFF
W
55
3
10
4
Litres
22
Maintenance
Time
OFF
ON (35/15)
W
55
3
10
2 min.
23
WASH
Drain
Time
ON
OFF
NO mov
Empty Elect.+ 14 sec.
(
The data are indicative
)
PW= Prewash
BL = Bleach
SF = Softener W = Wash