DISPLAY

A Room noise level indicator (when in audio position).
B High level of contamination. Set to (3) or auto.
C Medium level of contamination. Set to (2) or auto.
D Lower level of contamination. Set to (1) or leave at this setting.
E Indicates time to clean filters according to schedule.
F Indicates filter must be changed.
G Fan speed indicator.

4

H

D

E

F

C

C

C

G

I

FILTRATION STAGES

To ensure the highest quality of air, the air cleaner has a specially designed triple stage filtration
system. When air enters the unit, it passes through three filters and is then let out into the room
again.

Stage 1 Two pre-filters remove large particles such as strands of hair.
Stage 2 The electrostatic main filter (Reference No. EF100) removes smaller particles such

as pollen, mildew spores, dust.

Stage 3 Carbon filter, (Reference No. EF101). The carbon filter reduces the amount of gases

and odor (for example, tobacco smoke) from the indoor air. (The carbon filter will
reduce the air flow slightly.) The unit can be run without the carbon filter.

CAUTION: High voltage. Turn off the power switch and unplug before servicing.

This equipment should be inspected frequently and collected dirt
removed from it regularly to prevent excessive accumulation that may
result in flashover and/or risk of fire.

FOR BEST RESULTS

Place the air cleaner on the floor next to a wall. The air cleaner draws in air at floor level and blows
it out at the top. Place the air cleaner along the same wall as the room heater so that the rising
warm air coincides with the air flow of the cleaner. When using two or more units in one room,
place them along the same wall, as far apart as possible.

CAUTION: Do not place under a smoke detector. The cleaned air may delay the

smoke detector operation in the event of a fire.

FILTER CLEANING INTERVALS

Depending on the level of air contamination, we recommend that you follow the cleaning procedure
every two months or when the indicator on the display lights up.

The main filter may need cleaning more frequently if dust is visible on the upper filter surface.

Replace the main filter once a year or more frequently if necessary or when the indicator on the
display lights up.

When using the carbon filter, replace every three to six months or sooner if you are no longer able
to detect a reduction in odors.

A

B

C

D

E

F

G

Summary of Contents for Z7040

Page 1: ... Wire 6 Warranty 6 Customer Order Form 7 www electrolux com Electrostatic Air Cleaner Household Type Model Z7040 NOTE Please check to see if the corona wire assembly has been dislodged during shipping The shipping tape does not have to be removed to operate cleaner Please see page 5 and 6 for instructions ...

Page 2: ... off all controls before unplugging Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or air cleaner with wet hands Do not put any object into openings Do not use with any opening blocked keep free of dust lint hair and anything that may reduce airflow Do not use without filters in place Store your cleaner indoors in a cool dry area Do not use in humid place...

Page 3: ...tamination in the room Manual Mode C This position provides a manual setting for the fan speed O is off 3 is highest speed A B 3 MODEL TYPE SERIAL NO VOLTS AMPS HERTZ SERVICE INFORMATION USA1 800 282 2886 Canada 1 800 282 2886 Rating Plate The model type and serial number are indicated on the rating plate located on the back of the cleaner For prompt and complete service information always refer t...

Page 4: ...wer switch and unplug before servicing This equipment should be inspected frequently and collected dirt removed from it regularly to prevent excessive accumulation that may result in flashover and or risk of fire FOR BEST RESULTS Place the air cleaner on the floor next to a wall The air cleaner draws in air at floor level and blows it out at the top Place the air cleaner along the same wall as the...

Page 5: ...r a Open the access door As you remove filters one at a time clean each one as you remove it with a vacuum cleaner preferably fitted with a HEPA filter These filters can also be washed with a mild detergent Make sure they are completely dry before placing back in the unit Use your vacuum s brush nozzle to avoid damaging the filters After cleaning filters insert and close the door The pre filters d...

Page 6: ... by negligence abuse or use not in accordance with the Owner s Guide or defects or damages caused by unauthorized service or the use of other than authorized replacement parts White Consolidated Ltd will at its option repair or replace a defective cleaner or cleaner part that is covered by this warranty As a matter of warranty policy White Consolidated Ltd will not refund the consumer s purchase p...

Page 7: ...Paper Filter EF100 49 99 Carbon Filter EF101 24 99 Total prices subject to change without notice Tax add state and local taxes as required by law Postage and Handling Charge Within the U S A TOTAL 2002 White Consolidated Ltd Printed in Sweden Method of Payment No C O D s Check or money order payable to The Eureka Company Do not send currency Charge to my Visa 13 16 digits MasterCard 13 digits Amer...

Page 8: ...8228369 01 2002 White Consolidated Ltd Part No 72497A 3 03 Printed in Sweden ...