GAS CONNECTION

The cooker is fitted with 4 legs for an eventual alignment in height

with the furniture. To assemble them, it is necessary to raise the

cooker and to 

screw

 the four legs into the suitable threadings

placed on the corners on the bottom of the appliance.

Fig. 12

This appliance must be installed in accordance with the Gas Safety

(Installation and Use) Regulations (current edition) and the I.E.E

Wiring Regulations.

Detailed recommendations are contained in the following British

Standard Codes of Practice - B.S 6172, B.S 5440: Part 2 and B.S.

6891: Current Editions

For appliances installed in the Republic of Ireland please refer to

NSAI- Domestic Gas Installation I.S 813 Current Editions and the

ETCI Rules for Electrical Installations.

IMPORTANT

This cooker is supplied for use on 

Natural Gas Only

 and cannot

be used for any other gas without modification.

Conversion for use on LPG and other gases must only be

undertaken by a qualified person. For information for use on other

gases contact your local Service Centre.

The cooker must be installed by a qualified person in accordance

with the Gas Safety (Installation and Use) (Amendment) Regulations

1990 and the relevant building/I.E.E. Regulations.

Failure to install the appliance correctly could invalidate any

manufacturers warranty and lead to prosecution under the above

quoted regulations.

In the 

UK, CORGI

 registered installers are authorised to undertake

the installation and service work in compliance with the above

regulations.

Provision for Ventilation

The room containing the cooker should have an air supply in

accordance with BS 5440: Part 2: The room must have an opening

windows or equivalent; some rooms may also require a permanent

vent. If the room has a volume between 5 and 10m 3, it will require

an air vent of 50cm2 effective area unless it has a door which

opens directly to the outside. If the room has a volume of less

than 5m3, it will require an air vent of 100cm2  effective area. If

there are other fuel burning appliances in the same room, BS

5440: Part 2: 1989 should be consulted to determine air vent

requirements. Ensure that the room containing the cooker is well

ventilated, keep natural ventilation holes or install a mechanical

ventilation device (mechanical cooker hood). Prolonged intensive

use of the appliance may call for additional ventilation, for example

opening of a window, or more effective ventilation, for example

increasing the level of mechanical ventilation where present. This

cooker is not fitted with a device for discharging the products of

combustion. Ensure that the ventilation rules and regulations are

followed. Excess steam from the oven, vents out at the top back

edge of the cooker, so make sure that the walls behind and near

the cooker are resistant to heat, steam and condensation. Your

cooker must stand on a flat surface so that when it is in position

the hob is level. When in position check that the cooker is level

by using a spirit level and adjust the 2 feet at the rear and the 2

feet at the front if necessary. It is important that the cooker is

stable and level for the overall cooking performance.

Remember that the quantity of air necessary for combustion must

never be less than 2m3/h for each kW of power (see total power

in kW on the appliance data plate).

Gas Safety (Installation & Use) Regulations

It is the law that all gas appliances are installed by competent

persons in accordance with the current edition of the 

Installation

& Use Regulations

. It is in your interest and that of safety to

ensure compliance with the law.

In the UK, CORGI registered installers work to safe standards of

practice. The cooker must also be installed in accordance with

the current edition of BS 6172. Failure to install the cooker correctly

could invalidate the warranty, liability claims and could lead to

prosecution.

Gas Connection (all installation and service work must be

carried by a CORGI registered engineer)

Prior to installation, ensure that the local distribution conditions

(nature of the gas and gas pressure) and the adjustment conditions

are compatible. The adjustment conditions for this appliance are

stated on the rating plate, located on the inside the front appliance

drawer.

This appliance is not designed to be connected to a combustion

products evacuation device. Particular attention should be given

to the relevant requirements regarding ventilation.

Connection to the cooker should be made with an approved

appliance flexible connection to BS 669. Models for use with LPG

should be fitted with a hose suitable for LPG and capable of

withstanding 50mbar pressure. A length of 0.9 to 1.25m is

recommended. The length of hose chosen should be such that

when the cooker is in situ, the hose does not touch the floor.

The temperature rise of areas at the rear of the cooker that are

likely to come in contact with the flexible hose do not exceed

700C.

Gas pressure may be checked on a semi-rapid hob burner. Remove

the appropriate injector and attach a test nipple. Light the other

burners and observe that the gas pressure complies with the gas

standards in force.

Certain types of cookers can be connected to the supply both on

the right and left hand side at the rear of the cooker. To reverse

the position, remove the blanking plug and refit in the side not to

be used. On completion carry out a gas soundness.

ELECTRICAL CONNECTION

OK

NO

Fig. 13

INLET

STOP

This appliance must be installed by a qualified person in

accordance with the latest edition of the IEE Regulations and

in compliance with the manufacturer instructions.

Ensure that the voltage is the same as that stated on the rating

plate. The rating plate can be found on the back cover of this

book.

WARNING! THIS APPLIANCE MUST BE EARTHED

The cooker must be connected to a suitable cooker control unit

incorporating a double pole switch having a contact separation

of at least 3mm in all poles, which is adjacent to (but not above),

and not more than1.25m away from the cooker and easily

accessible. We recommend that the cooker circuit is rated to

20amps.

Cable type H05 RRF 3X 2.5mm2

Connecting the mains cable

Open the mains terminal block cover as shown over, unscrew the

cableclamp «A» and unscrew (not fully) the screws in the mains

terminal

block «L N E» which secure the three wires of the mains

cable.Fit the cable and refit the cable clamp «A» .

Allow sufficient cable length for the cooker to be pulled out for

10

All manuals and user guides at all-guides.com

Summary of Contents for ZANUSSI ZCM 1030 X

Page 1: ...ELECTRIC DOUBLE OVEN AND GRILL WITH GAS HOB ZCM 1030 X ZCM 1031 X INSTRUCTION BOOKLET All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...full of fat oil or use a lid DO NOT LEAVE UNATTENDED WHILE COOKING Do not place flammable or plastic items on or near the hob burners Do not use proprietary spillage collectors on the hob burners Do not use the cooker as a room heater Do not dry clothes or place other items over or near to the hob burners or oven doors Do not wear garments with long flowing sleeves whilst cooking Do not place infl...

Page 3: ... OF FIRE In case of fire close the main valve of the gas supply and switch off the electricity supply to the appliance and never pour water onto burning oil Do not store flammable products or aerosol containers near the burners and do not spray them near lit burners FOR YOU AND YOUR CHILDRENS SAFETY Do not store items that are attractive to children above or near the appliance Keep children well a...

Page 4: ...ermostat knob main oven 7 Control knob function second oven 8 Control knob rapide burner left 9 Control knob semirapide burner left 10 Control knob Triple crown burner 11 Control knob rapide burner right 12 Control knob semirapide burner right A Semirapide burner B Rapide burner C Triple crown burner D Hob top E Control panel F Door Handle G Oven door main oven H Oven door second oven I Adjustable...

Page 5: ...AVING TIPS The diameter of the pan bottom should correspond to that of the burner The burner flame must never extend beyond the diameter of the pan Use flat bottomed pans only Whenever possible keep a lid on the pan while cooking this will save energy Cook vegetables potatoes etc with as little water as possible to reduce cooking times Fig 1 USE OF THE ELECTRIC OVEN The first time the oven is used...

Page 6: ... the food We recommend monitoring your first attempts and checking the results as similar results are obtained by cooking the same dishes in the same conditions The following three tables I II and III provide guidelines 6 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 7: ...ting taste and smell It is ideal for delicate pastries Medium grill It is ideal for grilling and gratinating small quantities of traditional food The thermostat knob must be placed on the maximum position Full grill It is ideal for grilling and gratinating traditional food Set the thermostat control knob to the 200 C position Thermal grilling The air which is heated by the grill element is circula...

Page 8: ...s Cooking time cooking end time manual position clock minute minder times to be set up to 23 hours 59 minutes Fig 5 Display 4 figures 7 segments display for cooking times and time of day Cooking time and manual function saucepan symbol Automatic function AUTO Minutes minder bell symbol The symbols light up when the corresponding functions are selected Automatic use with cooking time and end time s...

Page 9: ... 450mm above and across the width of the cooker should be an incombustible material or easy clean surface such as ceramic tiles Any overhanging surface or cooker hood should be at least 750mm 28 above the cooker hob We do not recommend positioning the cooker below wall cupboards as the heat and steam from the cooker may cause damage to the cupboard and its contents The cooker may be located in a k...

Page 10: ...e Remember that the quantity of air necessary for combustion must never be less than 2m3 h for each kW of power see total power in kW on the appliance data plate Gas Safety Installation Use Regulations It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the Installation Use Regulations It is in your interest and that of safety to ensur...

Page 11: ...Nozzle Burners Power Watt Consum N Posizione type max min max 1 15 Rapide 3000 750 286 l h NATURAL 20 0 97 Semi rapide 1750 480 167 l h 0 72 Auxiliary 1000 330 95 l h 1 28 Triple crown 3300 1300 315 l h G P L 30 0 85 Rapide 3000 750 219 g h BUTANE 28 0 65 Semi rapide 1750 480 128 g h PROPANE 37 0 50 Auxiliary 1000 330 73 g h 0 93 Triple crown 3300 1300 241 g h MINIMUM FLOW ADJUSTMENT FOR CONTROL K...

Page 12: ...Tip Montagnani cod 536321 0105 All manuals and user guides at all guides com ...

Reviews: