DEFECTS SOLUTIONS
Display
Cause
Solução
OFF
Does not reach the
MasterTemp reliable
sensor signal
Check and replace if the sensor cable is unshielded.
Check grounding of the sensor cable.
Check and eliminate possible bad contact.
Temperature sensor replacement if damaged.
The sensor automatically returns to measurement mode when normalized to reset the MasterTemp press the SET key until
the display the word REST, then release and the Monitor will restart without losing the parameters set previously.
IMPORTANT RECOMMENDATIONS
Before putting into operation the equipment make the following recommendations:
1.
All sensors and the equipment must be grounded.
2.
The sensor and the properly grounded power prevent there malfunction or damage in cases of disturbances,
outbreaks, and inductions into the machine.
3.
Using the communication network (RS485) 120 Ohms resistors in 2 transmission line ends (beginning and
end) in order to generate potential difference required for proper operation of the communication network.
4.
Only use with MasterTemp original accessories accompanying equipment (TC Split core), as they have been
rigorously tested together to ensure maximum performance and efficiency in the functioning of the whole.
5.
Do not use the monitor directly in the SUN, whenever it is installed on the pitch is important to have a panel
with smoked glassso that ultraviolet rays that affect the frontal polycarbonate are filtered in this way it will be
extended equipment life.
WARRANTY STATEMENT
The MASTERTEMP ELECTRON two year warranty starting from the date of sale recorded on the invoice, with
coverage for any manufacturing defects that become improper or inappropriate applications intended.
EXCLUSION OF WARRANTY
The warranty does not cover transport costs for servicing, freight and insurance for product shipment faulty
indication or malfunction. They are not also covered the following events: natural wear of parts at continuous and
frequent use, damage to the outside caused by falls or improper packaging; attempt to repair / seal violation with
damage caused by persons not authorized by Electron and at odds with the instructions that are part of the technical
data.
Summary of Contents for MASTERTEMP
Page 1: ...DIGITAL TEMPERATURE MONITOR MASTERTEMP 1 Instructions Manual Manual de Instruções ...
Page 7: ...DIGITAL TEMPERATURE MONITOR MASTERTEMP 4 APPLICATION EXAMPLE ...
Page 8: ...DIGITAL TEMPERATURE MONITOR MASTERTEMP 5 CATALOG CODE DIMENSION ...
Page 9: ...DIGITAL TEMPERATURE MONITOR MASTERTEMP 6 WIRING DIAGRAM MASTERTEMP ...
Page 45: ...MONITOR DIGITAL TEMPERATURE MASTERTEMP 42 EXEMPLO DE APLICAÇÃO ...
Page 46: ...MONITOR DIGITAL TEMPERATURE MASTERTEMP 43 CÓDIGO DE CATÁLOGO DIMENSÕES ...
Page 47: ...MONITOR DIGITAL TEMPERATURE MASTERTEMP 44 DIAGRAMAS DE LIGAÇÃO MASTERTEMP ...