3.  SAFETY INFORMATION. 
 

This product has been designed for safe operation when used as detailed in 
accordance with the manufacturer’s instructions. 
 

NOTE:

 Failure to use this equipment in accordance with this instruction book may 

compromise your basic safety protection afforded by the equipment and may 
invalidate the warranty / guarantee. The warranty / guarantee does not cover 
damaged caused by faulty installation or misuse of the equipment. 

 

3.1.  Prevention of Fire and Electric shock. 

 

 

To prevent a risk of fire or electric shock, 

DO NOT

 open your 

product case without authorisation. Only qualified Service 
personnel should attempt to repair this Controller.   

 

 

 

Replace fuses only with the type as listed in section, Parts and 
Accessories and Technical Specifications. (See fuse type and 
rating). 

 

 

 

Ensure the Mains Power Supply conforms to rating found on the 
data plate located on the base of this product. 

 

 

 

Never

 Operate this equipment with out connection to earth / 

ground. Ensure the mains supply voltage is correctly earthed / 
grounded in accordance with current area legislation.  

 

 

 

Do not 

install or remove any heating apparatus from the controller 

whilst power is applied. 

 

3.2.  General Safe Operating Practice. 

   

 

Always follow good laboratory practice when using this  
equipment. Give due recognition to your company’s safety and 
legislative health & safety procedures and all associated legislation 
applicable to your areas of operation. Check laboratory procedures 
for substances being heated and ensure all hazards (e.g. explosion, 
implosion or the release of toxic or flammable gases) that might 
arise have been suitably addressed before proceeding.  When 
heating certain substances the liberation of hazardous gases may 
require the use of a fume cupboard or other means of extraction. 

 

 

 

Ensure equipment is used on a clean, dry, non-combustible, solid 
work surface with at least 300mm suitable clearance all around 
from other equipment. 

 

 

 

Do not

 position the product so that it is difficult to disconnect from 

the mains supply.  

 

 

 

Do not 

immerse unit in water or fluids.

 

 

 

 

Do not 

spill substances onto this unit. If spillage does occur, 

disconnect unit from mains supply and follow instructions as 
detailed in Section ‘Maintenance’.  

 

 

 

   

 

To prevent electronic overheat and potential fire  

Do not

 cover this product when connected to the mains power 

supply.  

 

 

 

It is 

not

 recommended to leave any heating apparatus unattended 

during operation. 

 

 

   

 

Only use Original Equipment manufacture’s spares and 
accessories. Ref Section 11.  

 

 

Summary of Contents for MC810B MKII

Page 1: ...Page 1 of 24 M6493 Issue 10 3 MC810B MKII DIGITAL TEMPERATURE CONTROLLER INSTRUCTION BOOK ...

Page 2: ...aration of Conformity Page 24 Appendix A Decontamination certificate Page 22 The copyright of this instruction book is the property of Bibby Scientific Limited This instruction book is supplied by Bibby Scientific Limited on the express understanding that it is to be used solely for the purpose for which it is supplied It may not be copied used or disclosed to others in whole or part for any purpo...

Page 3: ...by a plug in platinum resistance probe The sample temperature is displayed on the LED display This product is suitable for bench and retort stand mounting or wall mounting using the bracket and screws provided 1 3 The MC810B has a short mains output lead with an IEC socket to connect it to the resistive load An accessory extension mains lead is available where remote operation is required e g in a...

Page 4: ... should read and be familiar with this Instruction book in order to preserve the protection afforded by the equipment To prevent injury or equipment damage it is the manufacturer s recommendation that all persons using this equipment are suitably trained before use 2 2 Symbols Defined Caution risk of danger See note or adjacent symbol Protective conductor terminal to be earthed Do not loosen or di...

Page 5: ...e controller whilst power is applied 3 2 General Safe Operating Practice Always follow good laboratory practice when using this equipment Give due recognition to your company s safety and legislative health safety procedures and all associated legislation applicable to your areas of operation Check laboratory procedures for substances being heated and ensure all hazards e g explosion implosion or ...

Page 6: ...Plug and Lead set cable away from the heating apparatus being controlled Refer to Instructions book product data label for the resistive load of equipment to ensure controller is suitable for application Always observe the Manufacturer s operating and safety instructions for the equipment to be connected to the controller NOTE if this product is not used in accordance with the Manufacturer s Instr...

Page 7: ...moulded IEC plug and lead set May be different from illustration As Req 2 MC810B MKII Digital Controller 1 3 Instruction Book 1 4 Wall fixing Bkt x 1 and screws x 2 per bag 1 5 Temperature Probe 1 For future reference please record your products Serial and Model Numbers Serial Number Model Number ...

Page 8: ... fitted See Technical Specification Section 8 of this Instruction book 5 5 Check the voltage on the product data label of this unit Ensure the rating conforms to your local supply Only connect to resistive loads 1500Watts 230V AC or 750Watts 115V AC Refer to Technical Specification Section 8 of this Instruction book 5 6 This product must be connected to a mains supply source which incorporates an ...

Page 9: ...ormation For end users outside of the EU consult applicable regulations 6 4 This product should only be dismantled for recycling by an authorised recycling company This product and accessories must be accompanied by a completed Decontamination Certificate prior to any disposal Copies of the Certificate are available from your distributor of Bibby Scientific products or you may copy and enlarge fro...

Page 10: ...ins input IEC socket with fuses 3 3 digit LED display 4 Orange Neon power on indication lamp 5 Exit Standby button 6 Mains Output IEC plug 7 Earth protective conduct terminal 8 Temperature probe 9 On Off I O power switch 10 Retort rod clamp 11 Data plate label 12 Wall bracket clamp 13 5 Pin DIN socket for temperature probe Check the data plate label and ensure your mains electrical supply voltage ...

Page 11: ...he temperature is anywhere below set point and fully off when the temperature is anywhere above the desired set point 7 3 2 On Off Controller plus Hysteresis To prevent detrimental control chattering as the temperature crosses the set point an On Off differential or hysteresis can be added to the controller function When a hysteresis value is entered for example say 3 C the controller will switch ...

Page 12: ...nt temperature to be approached relatively smoothly with minimal overshoot 7 4 Front Panel Controls The MC810B controller has four front panel keys as described below 7 4 1 The key is used to increase the value of the parameter shown on the display or to scroll through the parameter menu 7 4 2 The key is used to decrease the value of the parameter shown on the display or to scroll through the para...

Page 13: ...justment is within the minimum SPL and maximum SPH limit To store the new value press button or wait 10 seconds To return to operational mode without saving the settings press the Exit standby button 7 8 Stand By 7 8 1 Press the button and wait for the 3 seconds The word OFF will be displayed To resume press the button once again for another 3 seconds and the display will return to normal operatio...

Page 14: ...band Increase 1SP the case of the heating control vice versa decrease 1SP in the case of refrigeration control and re start the process E2 timeout2 error the auto tuning has not ended within the maximum time allowed 1000 cycles Re start the auto tuning process and set a longer cycle time 1CT E3 temperature over range check the error was not caused by a probe malfunction then decrease 1SP in the ca...

Page 15: ...you select control with hysteresis parameters 1HY 1T0 and 1T1 are used With 1CM PD you select a Proportional Integral Derivative control mode parameters 1PB 1IT 1DT 1AR 1CT will be used 1CH REF HEAS Refrigerating REF or Heating HEA control mode 1CM HY 1HY 0 19 9 C OFF ON thermostat differential With 1HY 0 the output is always off 1TO 0 30min Minimum off time After output 1 has been turned off it r...

Page 16: ...d variations 1PF ON OFF Output state in case of probe failure OAU NON THR AL0 AL1 AUX output operation NON output disabled always off the next perameter will be ATM THR output programmed for second thermostat control the next parameter will be 2SM AL0 contacts open when an alarm condition occurs the next perameter will be ATM AL1 contacts make when an alarm condition occurs the next parameter will...

Page 17: ...ore alarm temperature warning SB NO YES Stand by button enabling INP 0mA 4mA Sensor input selection see table of input specifications RLO 19 9 RHI Maximum range values RLO takes the maximum value measured by the transmitter i e the value matching 1V 20mA RHI RLO 99 9 Maximum range vlue RHI takes the maximum value measured by the transmitter i e the value matching 1V 20mA OS1 12 5 12 5 Probe T1 off...

Page 18: ... Mains Power Lead set Europe 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord H0 V V F Replace only with equivalent cable Mains Power Lead set USA 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord SJT VW 1 Replace only with equivalent cable Lead set plug fuse UK only 13A BSEN1362 Mains Output Non detachable 3 core mains cable with moulded IE...

Page 19: ...reduce the effective life of this product and may cause a hazard Maintenance for the unit should include Periodic electrical safety testing an annual test is recommended as the minimum requirement Regular inspection for damage with particular attention to the mains lead and plug set Routine cleaning of the equipment should be undertaken using a clean cloth DO NOT USE SOLVENTS FOR CLEANING ANY PART...

Page 20: ...consult Customer Support Refer to section 10 If the equipment has been exposed to contamination the Responsible Body is responsible for carrying out appropriate decontamination If hazardous material has been spilt on or inside the equipment decontamination should only be undertaken under the control of the Responsible Body with due recognition of possible hazards Before using any cleaning or decon...

Page 21: ...es bibby scientific com Technical support electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 9243Tel 609 589 2560 Fax 609 589 2571 Email labproducts techneusa com Http www techneusa com 11 PARTS AND ACCESSORIES AZ9035 Fuse F8A Qty 10 230V AC Product AZ6747 Mains cord...

Page 22: ...eleting YES NO as applicable and by providing details in section 2 below A Blood body fluids Pathological specimens YES NO Provide details if YES B Biodegradable material that could become a hazard YES NO Provide details if YES C Other biohazard YES NO Provide details if YES D Chemical or substances hazardous to health YES NO Provide details if YES E Radioactive substances State name s and quantit...

Page 23: ...Page 23 of 24 M6493 Issue 10 3 12 NOTES ...

Page 24: ...ific Limited Beacon Road Stone Staffordshire ST15 0SA Great Britain Tel 44 0 1785 812121 Fax 44 0 1785 810405 General enquiries info bibby scientific com Order enquiries sales bibby scientific com Technical support electrothermalhelp bibby scientific com www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 9...

Reviews: