15
Step II –
laying
the heating cable
• A floor prepared for heating cable laying
should be smoothed, cleaned and primed,
which will enable hot-glueing the cable to
the floor surface.
• The temperature sensor cable should be fed
into the protective flexible conduit installed
in the preparation step. Seal the conduits
floor ending with a rubber stopper to protect
the sensor against moisture penetration.
• Lay the heating cable on the floor making
sure that it will not be positioned directly
under the fixed furniture, and fasten
the cable with the installation tape.
If the heating cable has been arranged
wrongly, you can peel off the installation
tape and change the cable's position.
•