installation box
temperature sensor
9
Primary heating
When selecting the heating cable,
it is necessary to consider:
• The heat demands of the room (necessary to
cover the heat losses and maintain the required
temperature level).
• The fixed-furniture-free floor area, where the
heating cable can be laid.
• The heating cables should be laid at the
maximum distance of 10 cm from one another,
so that the underheated or cold spots do not
occur.
• The heating cables should be laid at a minimum
distance of 4 cm from one another for the
UltraTec cable or 5 cm for the DM cable,
for ceramic tile finishing.
• The distance between the heating cables
for wooden floors, Vinyl or fitted carpet
should be 10 cm.
1
2
1
2
Summary of Contents for ELEKTRA DM
Page 2: ......
Page 28: ...ESG EN 403 Grupa V5 12 10 0 1 a www elektra eu ...
Page 30: ......
Page 56: ...ESG PL 403 Grupa V5 11 10 0 1 b www elektra pl ...
Page 58: ......
Page 84: ...ESG RU 403 Grupa V5 12 10 0 1 a www elektra otoplenie ru ...