45
Instruction Manual
PSI 8000 3U Series
EN
Date: 05-03-2012
About the device
PSI 8500-60 3U PSI 81000-30 3U PSI 8080-510 3U PSI 8200-210 3U PSI 8240-170 3U
Mains input
Input voltage range
340…460V AC
340…460V AC
340…460V AC
340…460V AC
340…460V AC
Input voltage range optional
-
-
588…796V AC +MP 588…796V AC +MP 588…796V AC +MP
Required phases
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
L1, L2, L3, PE
Input frequency
50/60Hz
50/60Hz
50/60Hz
50/60Hz
50/60Hz
Input fuse
4x T16A
4x T16A
6x T16A
6x T16A
6x T16A
Input current
max. 28A
max. 28A
max. 28A
max. 28A
max. 28A
Power factor
> 0.99
> 0.99
> 0.99
> 0.99
> 0.99
Output - Voltage
Nominal voltage U
Nom
500V
1000V
80V
200V
240V
Adjustable range
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
0V…U
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.02%
< 0.02%
< 0.02%
< 0.02%
< 0.02%
Stability at 0…100% load
< 0.05%
< 0.05%
< 0.05%
< 0.05%
< 0.05%
Ramp-up time 10...90% at 100% load
max. 30ms
max. 30ms
max. 30ms
max. 30ms
max. 30ms
Ripple @ BWL 20MHz
< 300mVpp
< 70mVrms
< 800mVpp
< 200mVrms
< 150mVpp
< 10mVrms
< 250mVpp
< 25mVrms
< 500mVpp
< 20mVrms
Accuracy*
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
100mV
1V
10mV
100mV
100mV
Remote sense compensation
max. 10V
max. 20V
max. 2.5V
max. 6V
max. 7.5V
Overvoltage protection
threshold (adjustable)
0…550V
0…1100V
0…88V
0…220V
0…264V
Output - Current
Nominal current I
Nom
60A
30A
510A
210A
170A
Adjustable range
0…I
Nom
0…I
Nom
0…I
Nom
0…I
Nom
0…I
Nom
Stability at mains fluctuation ±10%
∆
U
IN
< 0.05%
< 0.05%
< 0.05%
< 0.05%
< 0.05%
Stability at 0…100%
∆
U
OUT
< 0.15%
< 0.15%
< 0.15%
< 0.15%
< 0.15%
Ripple @ BWL 20MHz
< 33mApp
< 16mArms
< 22mApp
< 11mArms
< 900mApp
< 120mArms
< 167mApp
< 33mArms
< 333mApp
< 27mArms
Accuracy*
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
10mA
10mA
100mA
100mA
100mA
Transient recovery time 10….90% load
< 2ms
< 2ms
< 2ms
< 2ms
< 2ms
Output - Power
Nominal power P
Nom
10000W
10000W
15000W
15000W
15000W
Nominal power at derating
0...P
Nom
0...P
Nom
0...P
Nom
0...P
Nom
0...P
Nom
Accuracy*
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
≤
0.2%
Resolution of display
0.01kW
0.01kW
0.01kW
0.01kW
0.01kW
Efficiency
95.50%
95.50%
93%
95.20%
93%
Miscellaneous
Ambient temperature
0….50°C
0….50°C
0….50°C
0….50°C
0….50°C
Storage temperature
-20….70°C
-20….70°C
-20….70°C
-20….70°C
-20….70°C
Humidity rel.
< 80%
< 80%
< 80%
< 80%
< 80%
Dimensions (WxHxD) **
19" 3U 595mm
19" 3U 595mm
19" 3U 595mm
19" 3U 595mm
19" 3U 595mm
Weight
25.5kg
25.5kg
33kg
33kg
33kg
Redundancy
yes
no
yes
yes
no
Isooutput to enclosure
1000V DC
1500V DC
500V DC
500V DC
500V DC
Isolation -output to enclosure
Isolation input to output
Cooling
Safety
EMC standards
Overvoltage class
Protection class
Pollution degree
Operational altitude
Series operation
max. series connection voltage
Master-Slave
Parallel operation
max. parallel connection voltage
Master-Slave
Analogue programming
Input range
Accuracy
Input impedance
Article number
09230436
09230438
09230432
09230442
09230434
300V DC
1
2
by fans, air inlet on the front, air exhaust on the rear
EN 60950
EN 61326, EN 55022 Class B
2
<2000m
4200V DC
no
600V
1500V
yes, via Share bus
53kOhm
≤
0.2%
0…5V or 0…10V, selectable
* Related to the nominal value, the accuracy defines the maximum allowed deviation between set value and actual value.
Example: a 80V model has min. 0.2% voltage accuracy. This is 160mV. When setting a voltage of 5V and with an allowed maximum deviation of 160mV, the resulting
actual value could be between 4.84V and 5.16V.
** Enclosure dimensions only, not overall dimensions