Page 10
EA Elektro-Automatik GmbH
Helmholtzstr. 31-37 • 41747 Viersen
Germany
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
www.elektroautomatik.de
ea1974@elektroautomatik.de
PSI 9000 WR 3U Slave Series
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value
15 kW
Model WR Slave
PSI 9080-510
PSI 9200-210
PSI 9360-120
Internal resistance regulation
Adjustment range
0...5 Ω
0...28 Ω
0...90 Ω
Accuracy
(1
≤1% of max. resistance ± 0.3% of maximum current
Insulation
Allowed float (potential shift) on the DC output:
Negative terminal to PE
Max. ±400 V DC
±725 V DC
±725 V DC
Positive terminal to PE
Max. ±400 V DC
±1000 V DC
±1000 V DC
AC input <-> PE
2.5 kV DC
AC input <-> DC output
2.5 kV DC
Miscellaneous
Cooling
Temperature controlled fans, front inlet, rear exhaust
Ambient temperature
0..50°C
Storage temperature
-20...70°C
Humidity
< 80%, not condensing
Standards
EN 61010, EN 61326
Overvoltage category
2
Protection class
1
Pollution degree
2
Operational altitude
< 2000 m
Digital interfaces
Featured
1x USB (front side) for quick value setup
1x USB (rear side) for communication and service
Galvanic isolation from device
Max. 1500 V DC
Terminals
Rear side
Share Bus, DC output, AC input, remote sensing, USB, master-slave bus
Front side
USB
Dimensions
Enclosure (WxHxD)
19“ x 3U x 670 mm
Total (WxHxD)
483 x 133 x min. 776 mm
Weight
~ 32 kg
~ 32 kg
~ 32 kg
Article number
06280364
06280365
06280366