27
17 Technical data
Technical data
1)
KERCOMET 170 KERCOMET 210
MULTIMIG 150
Welding range (I
2min
…I
2max
)
A
15…170
25…210
15…150
Welding range (U
2min
…U
2max
)
V
15,3…22,5
15,3…24,5
14,8…21,5
No-load voltage
V
16,7…38,0
14,5…40,3
14,4…26,9
Voltage setting
steps
6
12
7
Slope characteristic
constant voltage characteristic line
ED 100 %
A
70
75
100
ED 60 %
A
85
90
120
ED at max. current
%
15
15
40
Usable wires steel
Ø mm
0,6…0,8
0,6…1,0
0,6…0,8
Usable wires aluminium
Ø mm
1,0
1,0…1,2
1,0
Usable wires CrNi
Ø mm
0,8
0,8…1,0
0,8
Usable wires CuSi
Ø mm
—
—
0,8…1,0
Wire feed rate
m/min
0,5…25
0,5…25
0,5…25
Mains
Mains voltage (50/60 Hz)
V 1~ 230 / 3~ 400
1~ 230 / 3~ 400
3~ 400
Positive mains voltage tolerance
%
15
15
15
Negative mains voltage tolerance
%
25
25
25
Input power S1 (100 %)
kVA
2,1
2,3
3,0
Input power S1 (60 %)
kVA
2,8
2,9
3,6
Input power S1 (max. Current)
kVA
6,7
9,0
4,5
Current input I
1
(100 %)
A
5,3
5,7
4,3
Current input I
1
(60 %)
A
6,9
7,3
5,2
Current input I
1
(max. Strom)
A
16,8
22,5
6,5
Maximum effective mains current I
1eff
A
6,5
8,7
4,3
Power factor (at I
2max
)
cos ф
0,89
0,89
0,89
Mains fuse (slow-response)
A
16
16
16
Mains plug
CEE 16
CEE 16
CEE 16
Machine
Protection class
(in accordance with EN 60529)
IP
23S
23S
23S
Insulation class
F
F
F
Cooling method
F
F
F
Noise emission
dB(A)
< 70
< 70
< 70
Dimensions and weights
Dimensions
mm
880 x 400 x 755
Weight
kg
65
69
66
Standard equipment
Feed unit
Rolls
2
4
2
Tab. 5:
Technical data
1
) measured at 40° C environmental temperature
2