Resistance Welder MULTISPOT MI-90 T
Troubleshooting
36
Symptom
Possible cause
Remedy
WHO should do
it?
LED red
The red LED indicates thermal
overloading of the spot welding
pliers or power source.
It is not possible to
continue working while the
LED is on. The unit is
ready for use again once
the tool, power source or
coolant has cooled down
and the LED has gone off
again.
Do not switch off the
unit and cooling during
the cooling-down phase
to prevent any heat
congestion.
Operator
7.2.2
Possible causes and remedies in case of unsatisfactory welding results
Symptom
Possible cause
Remedy
WHO should do
it?
Weld current too weak.
Weld spot too small
Weld time too short.
Adapt welding parameters. Operator
Weld current too high.
Welding spot burns up,
excessive spattering,
sheets not strong
enough.
Weld time too long.
Adapt welding parameters. Operator
Welding job flawed
Sheets may have been
insufficiently prepared.
"6.1.1"
Operator