24
EN
Operating and assembly instructions ND ATEX
www.elektror.com
9016324 01.20/09
*1)
min. value / max. value of characteristic curve
9 TECHNICAL
SPECIFICA
TIONS
Model
min.
V
olumetric
fl
ow
rate
max.
V
olumetric
fl
ow
rate
Total pressure dif-
ferential
Max. perm.
blower speed
Motor speed
V
oltage
Frequency
Power con-
sumption
Motor output
W
eight
Sound pres-
sure level L
A
*1)
[m³/min]
[m³/min]
[Pa]
[min
-1
]
[min
-1
]
[V]
[Hz]
[A]
[kW]
[kg]
[db (A)]
D 03
0,5
3,2
330
3000
2870
230/400
50
0,92/0,53
0,18
6,1
54 / 63
D 04
0,5
5,0
350
3000
2870
230/400
50
0,92/0,53
0,18
6,4
62 / 67
D 05
1,0
10,0
430
3000
2870
230/400
50
0,92/0,53
0,18
6,9
62 / 72
D 052
2,0
15,0
530
3000
2800
230/400
50
1,30/0,75
0,25
8,8
62 / 76
D 060
2,5
22,0
730
3000
2840
230/400
50
2,48/1,43
0,55
11,5
69 / 83
D 064
2,5
27,0
1050
3000
2830
230/400
50
4,50/2,60
1,1
16,1
73 / 81
D 066
5,0
38,0
1200
3000
2870
230/400
50
6,65/3,85
1,85
24,4
74 / 86
D 07
5,0
41,0
1200
3000
2870
230/400
50
6,65/3,85
1,85
25,6
76 / 81
D 072
10,0
48,0
1200
3000
2870
230/400
50
9,0/5,2
2,5
30,2
76 / 86
D 08
10,0
47,0
1700
3000
2870
230/400
50
9,0/5,2
2,5
35,2
79 / 84
D 082
10,0
62,0
1700
3000
2880
400
50
6,9
3,3
44,2
79 / 86
D 09
10,0
80,0
1900
3000
2925
400
50
10,4
5,5
81,0
87 / 95
D 092
10,0
95,0
1900
3000
2945
400
50
14,1
7,5
129,0
87 / 99