18
EN
Operating and assembly instructions RDF
www.elektror.com
9016315 01.20/12
Note!
Repairs must be carried out by the manufacturer.
We cannot accept any liability for repairs carried
out by third parties.
5.1
Conveyor blowers are subject to wear and must be
checked at regular intervalls, depending on the type of con-
veyed media. Wear parts such as the impeller should be re-
placed on time as bearings may be damaged by imbalance
due to uneven wearing.
5.2
Replacement of the impeller and cleaning work are car-
ried out by unscrewing of the housing cover. Power supply
must be cut o
ff
during this work. The impeller must be stand-
ing still and be secured against restarting.
5.3
There is no maintenance work necessary on the drive
motor. The lubrication of the enclosed deep-groove ball bear-
ings is su
ffi
cient for their entire service life.
5.4 Ball bearings
Note!
The fans from Elektror are equipped with sealed
deep groove ball bearings, which do not require
relubrication.
Note!
Check the ball bearings during servicing and
prior to recommissioning.
Operation is only permitted with
fl
awless ball
bearings!
Note!
In the event of frequently starting up and shutting
down, premature replacement of the bearings
will be required. Determining the time for repla-
cing the bearings is the sole responsibility of the
maintenance and servicing personnel, who must
make a safety judgement.
Devices
Minimum ball bearing service
life
Horizontal
motor shaft
Vertical motor
shaft
RD F range
22.000
Hours
11.000
Hours
Ball bearing change recommendation
- Prior to reaching the minimum service life
- 30 months following delivery at the latest
- Check after 6 months’ storage time; change if necessary
5.5 Seals and radial shaft sealing rings
If sealing elements and/or radial shaft seals are included
in the scope of delivery, for safety reasons they should be
replaced at each maintenance, where sealing elements are
opened removed or otherwise altered.
5.6 Cleaning
There is a high risk of injury on the inside of the device due to
rotating parts during operation. Decommission the device in
all cases and wait until all moving parts have stopped before
opening, reaching in or inserting tools into the device. Secure
the device reliably against it being accidentally restarted dur-
ing the entire period.
Also make sure that no other dangerous situation can arise
when restarting after a standstill, e.g. as a result of a power
failure or blockages.
Cleaning or maintenance must not lead to damage or modi-
fi
cations to the device and its components that would in
fl
u-
ence safety or health protection and, for example, impair the
balanced state of the impeller.
When starting up the blower, make sure that all tools or other
foreign objects have been removed from inside the device
and that all covers and protective grilles have been attached
correctly.
6 SAFETY RELATED INFORMATION
ON TAKING OUT OF OPERATION AND
REMOVAL
The disconnection of all electrical connections and any other
electrical work in connection with decommissioning must
only be carried out by a quali
fi
ed electrician.
The device should be dismantled only when all rotating parts
have come to a standstill and cannot be restarted.
The guidelines set out in 2.1 Transport and Handling must be
observed when dismantling and removing it.
Treat the device as industrial waste when disposing of it.
The device parts are made of recyclable material, such as
aluminium, (stainless) steel, copper and plastic. However,
there are components that need special treatment (e.g. fre-
quency converters). The statutory national and local disposal
and recycling regulations must be observed.
7 LIABILITY AND EXCLUSION OF
LIABILITY
The owner shall bear the responsibility for the correct use of
the device.
Elektror shall not accept any liability for any use of its prod-
ucts and components which is contrary to their intended use.
This shall also apply in particular to use in special applica-
tions and under operating conditions that have not been spe-
ci
fi
cally agreed with Elektror.
Elektror shall not accept any liability for any modi
fi
cations or
alterations to the device or accessories supplied.
Likewise, Elektror shall not be liable for improper, delayed,
neglected maintenance. Neither shall it be liable for any
cleaning and repair work not carried out by quali
fi
ed Elektror
specialists, nor for the possible consequences.