15
www.elektror.com
Operating and assembly instructions SVD
9016318 07.20/10
EN
Measurement at the
fl
ange bearing shield, preferably
near the bearing
= Measuring point
= Measuring
direction
Maximum permissible vibration speed
(Limit values according to ISO 14694:2003 (E),
category BV-3)
Rigidly mounted
[mm/s]
Flexibly mounted
[mm/s]
E
ff
ective value
[r.m.s.]
E
ff
ective value
[r.m.s.]
At installation
Start-up
4.5
6.3
Alarm
7.1
11.8
Shut-down
9.0
12.5
• Firmly screw down the feet on blowers at the place of use onto
a suitable
fi
rm level load-bearing base free from transmis-
sion of vibratory or shock loads.
• Other standards and regulations must be observed
depending on the application.
• Blower feet and consoles must be designed only for the
respective blower’s own weight.
• Cover the open air intake and discharge with protective
grilles according to DIN EN ISO 13857.
• Ensure that the motor has adequate ventilation.
Permitted ambient temperatures with:
Standard model with Elektror motor and a rated
frequency of 50 Hz or 60 Hz:
• Ambient temperature -20°C to +60°C
Note!
The rated e
ffi
ciencies and the e
ffi
ciency classes
of the motors are given as per IEC 60034-2-1 for
operation at an ambient temperature of 25°C.
As per IEC 60038 Elektror motors are generally
designed for an extended voltage range of ±10%.
However, the stated e
ffi
ciency relates to the rated
voltage, i.e., the extended tolerance is not taken
into account.
Special voltages, multi-voltage motors, models suitable for
frequency converters, FUK models, devices with UL approv-
al, devices with Aircontrol and other motor makes:
• Ambient temperature -20°C to +40°C
• Voltage tolerance ±5% (For exceptions, see „4.2 Fre-
quency converter operation“)
• The drive motor ventilation system must not be a
ff
ected by
the installation situation.
Minimum distance to the blower cover (for the intake of
cooling air)
Drive power
Minimum distance
to the blower cover
[mm]
[inches]
≤
1.5 kW
34
1.34
> 1.5 kW
53
2.09
3.3 Electrical connection
Note!
The work described in this section may only be
performed by a quali
fi
ed electrician. Connect the
appliance as per the circuit diagram in the termi-
nal box and in accordance with the relevant local
requirements.
Three-phase or single-phase a.c. motors are used as drive
motors. In the equipment identi
fi
ers, the letter D denotes
three-phase (3~) and E denotes single-phase (1~).
• The drive motor must be protected by a motor circuit break
er (not applicable for units powered by frequency convert-
er). With units powered by frequency converter, the exist-
ing temperature sensor (PTC thermistor detector) or
temperature monitor (break contact) is to be connected to
the converter and evaluated.
• Checking that the supply voltage matches the details on
the rating plate.
• The safety earth terminal can be found in the terminal box.
Note!
The following information should also be ob-
served when operating the drive motor with a
frequency converter:
• Only motors must be used on the frequency
converter that are marked on the rating plate with
the option “/FU”, “suitable for use with a frequen-
cy converter” or that were ordered and con
fi
rmed
as “suitable for use with a frequency converter”.
• The frequency converter supply voltage must
only be a maximum of 400 V without the motor
fi
lter. Appropriate measures such as a motor
fi
lter
to protect the motor must be installed on the
motor terminals with higher frequency converter
supply voltages, longer lines and/or if the pulse
voltages are exceeded (max. 1000 Vpk for drive
motors up to 0.75 kW, maximum 1300 Vpk for
drive motors larger than 0.75 kW) Please contact
the converter supplier in this case. If a motor
fi
lter
is included in the delivery, this must be installed
between the converter and the motor. Please
ensure that there is su
ffi
cient space in the switch
cabinet and take into account the installation and
assembly requirements in the operating instruc-
tions of the frequency converter/motor
fi
lter
manufacturer.
• The maximum cable length between the mo-
tor and switch cabinet frequency converter (e.g.
Lenze Vector, Omron MX2 and Omron RX) must
not exceed 20 m. Maximum cable lengths of up to
3 m are permitted with Kostal INVEOR frequency
converters installed close to the motor and up to
10 m with Lenze MOTEC frequency converters.
Further information on wall mounting close to the
motor can be found in the original operating and
assembly instructions of the respective frequen-
cy converter manufacturer. The electrical con-
necting cables between the motor and frequency
converter in the above cases must be suitable
shielded cables, laid using the shortest route and
without clamping and plug-in connections and
connected correctly at both sides.
• The shielding braid in the connecting cables
must be connected fully, continuously and on
both sides, i.e. to the frequency converter and
motor, and at low resistance and permanently to
protective earthing systems or the main earthing