Operating and assembly instructions SVD

9016318 07.20/10

EN

Measurement at the 

fl

 ange bearing shield, preferably 

near the bearing

= Measuring point

= Measuring 

   direction

Maximum permissible vibration speed

(Limit values according to ISO 14694:2003 (E),
category BV-3)

Rigidly mounted 

[mm/s]

Flexibly mounted 

[mm/s]

E

 ective value

[r.m.s.]

E

 ective value

[r.m.s.]

At installation

Start-up

4.5

6.3

Alarm

7.1

11.8

Shut-down

9.0

12.5

•   Firmly screw down the feet on blowers at the place of use onto 

 a suitable 

fi

 rm level load-bearing base free from transmis-

  sion of vibratory or shock loads.
•  Other standards and regulations must be observed

  depending on the application.
•  Blower feet and consoles must be designed only for the

  respective blower’s own weight.
•  Cover the open air intake and discharge with protective

  grilles according to DIN EN ISO 13857.
•  Ensure that the motor has adequate ventilation.

  Permitted ambient temperatures with:

  Standard model with Elektror motor and a rated

  frequency of 50 Hz or 60 Hz:

  • Ambient temperature -20°C to +60°C

Note!

The rated e

  ciencies and the e

  ciency classes 

of the motors are given as per IEC 60034-2-1 for 

operation at an ambient temperature of 25°C.

As per IEC 60038 Elektror motors are generally 

designed for an extended voltage range of ±10%. 

However, the stated e

  ciency relates to the rated 

voltage, i.e., the extended tolerance is not taken 

into account.

Special voltages, multi-voltage motors, models suitable for 

frequency converters, FUK models, devices with UL approv-

al, devices with Aircontrol and other motor makes:
  • Ambient temperature -20°C to +40°C
  • Voltage tolerance ±5% (For exceptions, see „4.2 Fre-

quency converter operation“)
•  The drive motor ventilation system must not be a

 ected by 

  the installation situation.

Minimum distance to the blower cover (for the intake of 

cooling air)

Drive power

Minimum distance 

to the blower cover 

[mm]   

[inches]

 1.5 kW

34

1.34

> 1.5 kW

53

2.09

3.3 Electrical connection

Note!

The work described in this section may only be 

performed by a quali

fi

 ed electrician. Connect the 

appliance as per the circuit diagram in the termi-

nal box and in accordance with the relevant local 

requirements.

Three-phase or single-phase a.c. motors are used as drive 

motors. In the equipment identi

fi

 ers, the letter D denotes 

three-phase (3~) and E denotes single-phase (1~).
•  The drive motor must be protected by a motor circuit break

  er (not applicable for units powered by frequency convert-

  er). With units powered by frequency converter, the exist-

  ing temperature sensor (PTC thermistor detector) or 

  temperature monitor (break contact) is to be connected to 

  the converter and evaluated.
•  Checking that the supply voltage matches the details on 

  the rating plate.
•  The safety earth terminal can be found in the terminal box.

Note!

The following information should also be ob-

served when operating the drive motor with a 

frequency converter:
• Only motors must be used on the frequency 

converter that are marked on the rating plate with 

the option “/FU”, “suitable for use with a frequen-

cy converter” or that were ordered and con

fi

 rmed 

as “suitable for use with a frequency converter”.
• The frequency converter supply voltage must 

only be a maximum of 400 V without the motor 

fi

 lter. Appropriate measures such as a motor 

fi

 lter 

to protect the motor must be installed on the 

motor terminals with higher frequency converter 

supply voltages, longer lines and/or if the pulse 

voltages are exceeded (max. 1000 Vpk for drive 

motors up to 0.75 kW, maximum 1300 Vpk for 

drive motors larger than 0.75 kW)  Please contact 

the converter supplier in this case. If a motor 

fi

 lter 

is included in the delivery, this must be installed 

between the converter and the motor. Please 

ensure that there is su

  cient space in the switch 

cabinet and take into account the installation and 

assembly requirements in the operating instruc-

tions of the frequency converter/motor 

fi

 lter 

manufacturer.
• The maximum cable length between the mo-

tor and switch cabinet frequency converter (e.g. 

Lenze Vector, Omron MX2 and Omron RX) must 

not exceed 20 m. Maximum cable lengths of up to 

3 m are permitted with Kostal INVEOR frequency 

converters installed close to the motor and up to 

10 m with Lenze MOTEC frequency converters. 

Further information on wall mounting close to the 

motor can be found in the original operating and 

assembly instructions of the respective frequen-

cy converter manufacturer. The electrical con-

necting cables between the motor and frequency 

converter in the above cases must be suitable 

shielded cables, laid using the shortest route and 

without clamping and plug-in connections and 

connected correctly at both sides. 
• The shielding braid in the connecting cables 

must be connected fully, continuously and on 

both sides, i.e. to the frequency converter and 

motor, and at low resistance and permanently to 

protective earthing systems or the main earthing 

Summary of Contents for SVD 10

Page 1: ...SVD Sonderventilator Betriebs und Montageanleitung DE Special blower Operating and assembly instructions EN SVD 8 SVE 8 SVD 10 SVE 10 SVD 12 SVE 12 SVD 14 SVD 16 www elektror com...

Page 2: ...im Betrieb besondere Gefahren ausgehen k nnen d rfen nicht gef r dert werden z B brennbare St ube explosible Sto e che misch instabile Sto e oder Sto gemische die miteinander reagieren k nnen Der Eins...

Page 3: ...etreiber vor direktem Ber hren gesch tzt werden Verbrennungsgefahr 1 9 Motorschutzschaltung Vor Inbetriebnahme des Ventilators muss der Antriebsmotor mit einem Motorschutzschalter abgesichert werden g...

Page 4: ...esetzt werden Ventilator nicht ungesch tzt im Freien lagern vor Feuchtigkeit sch tzen Hebezeug sicher anschlagen Nur Hebezeuge und Last aufnahmeeinrichtungen mit ausreichender Tragf higkeit verwenden...

Page 5: ...4 2 Frequen zumrichterbetrieb Das Bel ftungssystem des Antriebsmotors darf nicht durch die Einbausituation beeintr chtigt werden Minimaler Abstand L fterhaube f r Ansaug K hlluft Antriebsleistung Min...

Page 6: ...Motoren ber 3 0 kw sind f r Stern Dreieck Anlauf am Ver sorgungsnetz vorgesehen F r direktes Einschalten hoher Kurzschlussstrom im Einschaltaugenblick bitte die Bedin gungen mit Ihrem Energieversorgun...

Page 7: ...folgendeU f ZuordnungamUmrichtereinzustellen fB und UB siehe Leistungsschild Bei Nichtbeachtung steigt der Motorstrom berproportional an und der Antriebsmotor kommt nicht auf Bemessungsdrehzahl Warnun...

Page 8: ...eit von den Einsatz Umge bungsbedingungen und ggf Vorgaben des Umweltschutzes zu berpr fen D h die Durchl ssigkeit der Filter ist vom Be treiber zu gew hrleisten 5 4 Reinigung Durch rotierende Teile b...

Page 9: ...estgestellt wurde dass die Maschine in die die unvollst ndige Maschine eingebaut werden soll den Bestimmungen der Maschinenrichtlinie 2006 42 EG entspricht Die folgenden harmonisierten Normen wurden a...

Page 10: ...400 60 3 55 2 05 0 90 21 78 89 NEMA 27 0 1500 3430 277 480 60 2 95 1 71 0 90 21 78 89 SVE 10 27 0 1400 2800 230 50 5 00 0 72 20 450 22 77 86 6204 6204 27 0 1500 3420 230 60 5 80 0 88 20 450 22 78 89 S...

Page 11: ...11 www elektror com 9016318 07 20 10...

Page 12: ...substances or mixtures of substances which can react with one another Use of the blowers for aggressive abrasive sticky toxic potentially explosive or very moist media is not permissible The temperat...

Page 13: ...nsor PTC thermistor detector or temperature monitor break contact is to be connected to the converter and evaluated 1 10 Noise development Note Wear hearing protection during operation at a dai ly exp...

Page 14: ...The frequency converter must never be used to lift the device or as a climbing aid 2 2 Storage Ensure that the air intake connection and pressure connec tion are closed Store the blower in its origina...

Page 15: ...be protected by a motor circuit break er not applicable for units powered by frequency convert er With units powered by frequency converter the exist ing temperature sensor PTC thermistor detector or...

Page 16: ...stalled in other machines or systems by qualified personnel i e not intended for consumers The manufacturer of the final system machine must guarantee confirm that the final system machine complies wi...

Page 17: ...fety instructions described in the respective operating or application manuals provided by the frequency converter supplier to guarantee a safe and trouble free operation It is also important to note...

Page 18: ...e device Secure the device reliably against it being accidentally re started during the entire period Also make sure that no other dangerous situation can arise when restarting after a standstill e g...

Page 19: ...that the machine in which the partially completed machine is to be installed complies with the provisions of the Machinery Directive 2006 42 EC The following harmonised standards were applied DIN EN...

Page 20: ...1 71 0 90 21 78 89 SVE 10 27 0 1400 2800 230 50 5 00 0 72 20 450 22 77 86 6204 6204 27 0 1500 3420 230 60 5 80 0 88 20 450 22 78 89 SVD 12 IE3 35 0 1600 2830 230 400 50 4 00 2 30 1 10 25 78 90 6204 62...

Page 21: ...21 www elektror com 9016318 07 20 10...

Page 22: ...nd Ger te Typ Leistungsschild When ordering please state Serial no rating plate and blower type rating plate Geh usestellungen Die Geh usestellung des Ventilators ist f r die Bestellung einiger Ersatz...

Page 23: ...eld 27 Schraube Screw 28 L fterfl gel Blower blade 29 Schraube Screw 30 Sicherungsring Circlip DE EN Pos Benennung Designation 1 Schraube Screw 2 Geh usedeckel Housing lid 3 Schraube Screw 4 Federring...

Page 24: ...www elektror com Elektror airsystems gmbh Hellmuth Hirth Str 2 73760 Ostfildern Postfach 1252 73748 Ostfildern Telefon 49 711 31973 0 Telefax 49 711 31973 5000 info elektror de 9016318 07 20 10...

Reviews: