13
INSTALLER INFORMATION
Terminal Locations Roof Termination
“Distance” = minimum distance required for positioning of the outlet to avoid adverse effects
with respect to:
A.
A ventilation opening serving an occupied room, a toilet or a bathroom
B. A heating air supply, when the supply flows through an occupied room.
C.
A window that can be opened and that is near an occupied room, a toilet or a bathroom.
(*)
If the required distance cannot be achieved, the outlet position rules take precedence.
(**) If the outlet is positioned at least 1 m higher than the intake supply opening, or a window
that can be opened.
(***) If the required distance cannot be achieved, the position of the outlet must be at least 1 m
above the highest facade/roof.
Important note for Roof Terminations (C31).
When installing the appliance with a roof termination (classification C31), it is important to fit a
flue restriction strip across the flue outlet inside the stove, see following notes.
Minimum Vertical Length notes.
Roof terminations may be installed from a minimum height 1.0 m this is shown on the pages that
follow.
To avoid adverse effects
Distance: outlet -
A,B or C
At the same roof level
>6 m (*)
At a different roof level
>3 m (*) (**)
At a lower positioned wall
>2 m (**)
At a higher sloping surface
>6 m (***)
Summary of Contents for Bidore
Page 15: ...15 installer information ...
Page 16: ...16 installer information ...
Page 17: ...17 installer information ...
Page 18: ...18 installer information ...
Page 34: ...34 Technical drawings techniCAL INFORMATION Trisore 95 Bidore 95 ...
Page 35: ...35 technical information Bidore 70 Trisore 70 ...
Page 40: ...40 Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands ...