10
SPECIFICATIONS and DIMENSIONS
Element4 Gas Fireplaces Rev# 07022020
European
Home
.com
APPLIANCE RATINGS
Mode
l
Modore 240 MKII
Tenore 240 MKII
Gas
Natural Gas Propane
Input Maximum
Btu/hr
88,000
64,800
Input Minimum
Btu/hr
26,000
19,500
Maximum Supply
Pressure
in. w.c.
10
12
kpa
2.49
2.99
Minimum Supply
Pressure
in. w.c.
4
8
kpa
1
2
Manifold Pressure
Maximum
in. w.c.
3.4
10.8
kpa
0.84
2.69
Manifold Pressure
Minimum
in. w.c.
0.4
1.5
kpa
0.1
0.37
Main Burner Injector Marking
1200 (x3)
240 (x3)
Pilot Injector Marking
32.2
27.1
Efficiency
85.3%
This product was tested and listed to
ANSI Z21.11.50a-2008 and CSA2.22a-2008
“Vented Gas Fireplaces” by Intertek Group.
(Figure 3)
A sample listing label image is shown
above. A
metal
listing label is attached
to every Element4 fireplace and contains
important certification information.
The
listing label must not be removed from
the fireplace.
Figure 2