Contents
1. Safety Information
3
2. Introduction
4
3. Features
5
4. Specifications
5
4-1 General Specifications
5
4-2 Measurement Specifications
6, 7
5. Operation
8
5-1 Preparation and Caution before Measurement 8
5-2 Front Panel Description
8, 9
5-3 How to Make Measurements
10-13
6. Maintenance
14
6-1 Battery Replacement
14
6-2 Fuse Replacement
15
6-2. Fuse Replacement
This meter is provided with a 200mA/250V fuse to
protect 200
m
A, 2000
m
A, 20mA, 200mA ranges.
NOTE: The 10A circuit is not fused.
1. Turn off the power.
2. Remove the two screws from the back of the case.
3. Remove the fuse from the holder and replace it with
a new fuse of the specified value.
Fuse Numbers
• 200mA/250V Bussman Fuse #GMA 2/10
• 200mA/250V Little Fuse #235-200
• 200mA/250V Elenco Fuse #530020
!
WARNING
!
PLEASE READ THIS INSTRUCTION
MANUAL CAREFULLY
Misuse and/or abuse of this instruction cannot be
prevented by any printed word and may cause
injury and/or equipment damage.
Please follow all these instructions and
measurement procedures faithfully, and adhere to
all standard industrial safety rules and practices.
-2-
-15-
CAUTION
Failure to turn off the DMM before installing
the battery could result in damage to the
meter if the battery is connected to the
battery terminal incorrectly.
Summary of Contents for M-1000B
Page 9: ...1 2 6 3 5 4 9...