WIRE SWITCH AND FUSE HOLDER (see Figure U)
Fuse
r
Slide the line cord bushing onto the line cord as shown in Figure U.
r
Spread the three line cord wires apart 6” from the end.
r
Strip the insulation off of both ends of the 6” red wire to expose 1/4” of bare wire. Pass the wire through the
1/2” diameter shrink tubing. Attach one end to the side lug on the fuse holder and then solder into place.
r
Strip 1/4” of insulation off of the smooth edged line cord wire. Pass the smooth edged line cord wire through
the 1/2” diameter shrink tubing and attach to the end lug on the fuse holder, solder into place.
r
Slide the shrink tubing over the fuse holder covering both lugs. Shrink the tubing for a snug fit. You may use
a hair dryer, heat gun (at lowest setting or you will melt the tubing) or the heat emitting from your soldering
iron (do not touch the tubing or the wires with the iron).
Switch
Disconnect the connector for the transformer.
r
Pass the 6” strip of red wire (leading from the side lug of the fuse holder), the (A) and (B) black transformer
wire, and the ribbed line cord wire through the 3/4” diameter piece of shrink tubing.
r
Cut the 2” section of 3/16” diameter shrink tubing in half to create two 1” sections. Slide a 3/16” diame-
ter piece of shrink tubing over the loose end of the red wire. Attach the red wire to lug 1 on the switch
and then solder into place.
r
Pass the black transformer wire labeled (B) through a 3/16” diameter piece of shrink tubing. Attach the wire
to lug 2 on the switch and then solder into place.
r
Slide the shrink tubing over lug 1 and lug 2 on the switch. Shrink the tubing into place.
r
Strip the insulation off of the black transformer wire (A) and the ribbed edged line cord wire to expose 1/2” of
bare wire. Twist the two bare wires together. Pass the wires through the 1/4” diameter piece of shrink tub-
ing. Attach the wires to lug 3 on the switch and solder into place. Slide the tubing over the lug. Shrink the
tubing into place.
r
Slide the 3/4” diameter shrink tubing over the switch and shrink into place.
r
Reconnect the connector for the transformer.
Switch Pin-out
1
2
3
Fuse Holder
Side Lug
6” Red Wire
1/2” Dia. Shrink Tubing
3/16” Dia. Shrink Tubing
(B) Black Transformer Wire
Female Connector
(A) Black Transformer Wire
Smooth Line Cord Wire
Ribbed Line Cord Wire
Green Line Cord Wire
Solder Lug
3/4” Dia. Shrink Tubing
1/4” Dia. Shrink Tubing
Switch
Figure U
-14-
Bushing
Summary of Contents for XK-550K