User Manual
EM303B General Purpose Inverter
48
Flashing
DATA
ENTER
DATA
ENTER
DATA
ENTER
DATA
ENTER
DATA
ENTER
DATA
ENTER
DATA
ENTER
RES
ESC
RES
ESC
Figure 4-8 Procedures for Viewing Fault Monitoring Code
4.2.8
Multi-functional Button
JOG
+/-
When F0-21=0, inverter runs as per setting jog frequency when pressing
JOG
+/-
, and will stop
immediately when releasing
JOG
+/-
.
When F0-21=1, the running direction of forward /reverse will be switched when pressing
JOG
+/-
.
4.2.9
Start/Stop
If F0-04=1, start/stop of inverter is selected as keypad control mode. When pressing
RUN
and
released, inverter starts to run. In operation status, inverter will stop immediately when
pressing
STOP
RESET
.
4.2.10
SwitchingMonitoring Display Code
If inverter is running or in ramp-to-stop status, and the present selected function code varies
with the status of inverter (F4-18=1), press
SHIFT
for 1.5 seconds, the monitoring display code
will varies with the setting values of F4-20~F4-23.
4.2.11 Display of Scientific Notification
If the display data of F0-00 or C0-00 is more than 5 bits, LED will display in scientific
notification. For instance: if the speed is 180000rpm, LED display is
which
refers to 180*10
3
.