User Manual
EM303B General Purpose Inverter
57
No.
Function
Range
Unit Default Type S/N
F2-26
M1Output Upper Limit
0.00
~
100.00
%
100.00
●
91
F2-27
M1 Output Gain
0.00
~
300.00
%
95.00
●
92
F2-28
~F2-31
Not used
Table 6-1 Functions of Numeric Multi-function Input Terminals
No.
Function
No.
Function
0 Disabled
26 Not Used
1 RUN-run
27
Switching Speed Input Setting to Primary
Speed Setting
2 F/R Forward/Reverse
28
Switching Speed Input Setting to Auxiliary
Speed Setting
3 Preset Speed Terminal 1
29
Switching Primary Speed Setting to Regular
Speed Setting
4 Preset Speed Terminal 2
30
Switching Regular Speed Input Setting to
Numeric Speed Input Setting
5 Preset Speed Terminal 3
31
Switching Jog Input Setting to Jog Numeric
Speed Input Setting
6 Preset Speed Terminal 4
32 Not Used
7 Acceleration/Deceleration Time Terminal 1
33 Not Used
8 Acceleration/Deceleration Time Terminal 2
34 Not Used
9 Coast to Stop
35
Switching Regular Torque Input Setting to
Numeric Torque Input Setting
10 Inverter Fault Reset
36 Not Used
11 Forward Jog FJOG
37 PID Positive/Negative Setting Switch
12 Reverse Jog RJOG
38 Not Used
13 Terminal UP
39 Not Used
14 Terminal DOWN
40 Not Used
15 UP/DOWN Clearing
41 Not Used
16 Acceleration/Deceleration Prohibited
42 Not Used
17 Ramp to Stop
43 Not Used
18 3-wire Sequence Stop Control (Pulse Stop)
44 Preset Current Limit Terminal 1
19 Not Used
45 Preset Current Limit Terminal 2
20
Switching Drive Control Mode to V/F Control
Mode
46 Preset Current Limit Terminal 3
21
Switching Run Command to Terminal Control
Mode
47 Start Wobbulation Operation
22 Run Command Input 0
48 Not Used
23 Run Command Input 1
49 Program Operation Reset(Reset Time,Pulse)
24
Switching Input Control Mode to Speed Control
Mode
50 Alternate Motor Switching Command
25
Switching Input Control Mode to Torque Control
Mode
51 External Fault Input