User Manual
EM303B General Purpose Inverter
66
UL
:
Overvoltage stall
Cl
:
Overcurrent stall
E0-23
Working Time at Fault
HOUR
0
×
567
E0-24
The 3
rd
Most Recent Fault
Fault trips
0
×
568
E0-25
Output Frequency at Fault
XX.XX/XX.X
Hz
0.00
×
569
E0-26
Output Current at Fault
XXX.X
A
0.0
×
570
No.
Function
Range
Unit Default Type S/N
E0-27
DC Bus Voltage at Fault
XXXX
V
0.0
×
571
E0-28
Running Direction at Fault
For
:Forward
rEu
: Reverse
0
×
572
E0-29
Running Status at Fault
ACC
: Acceleration
COn
: Constant Speed
dEC
: Deceleration
0
×
573
E0-30
Stall Status at Fault
0
: Normal
Ul
: Overvoltage stall
Cl
: Overcurrent stall
0
×
574
E0-31
Working Time at Fault
HOU
R
0
×
575
Section 2 Advanced Parameters
7.1.2
F6 Group:Simple PLC Function
No.
Function
Range
Unit
Default Type S/N
F6-00
Program Operation Mode
Ones place: Options of programmable
speed operation mode
0: Monocycle
1: Run as per Preset Speed 7 after
monocycle
2: Limited times of continuous cycle
3: Continuous cycle
Tens place: Not used
Hundreds place: Not used
Thousands place: Options of restart after
operation paused
0: Restart from the section when it
paused
1: Restart from Preset Speed 1
Ten thousands place:
Program operation time unit
0: S 1: min
00000
〇
192
F6-01
Preset Program Operation
Section 1
Ones place: Motor running direction
options
0: Forward1: Reverse
Tens place: Options of acceleration
/deceleration time
0: Acceleration / Deceleration time 1
1: Acceleration / Deceleration time 2
2: Acceleration / Deceleration time 3
3: Acceleration / Deceleration time 4
100
〇
193