5.3 Connection example SunTop 230 V/50 Hz
PE
N
L1
1 0 2
sw
br
bl
gr/
ge
1
2
3
4
7
6
Wicklungsthermostat
Geräteschalter
Abzweigdose
Schalterdose
Jalousieschalter/Jalousietaster
Elektronik
Kondensator
sw schwarz
br braun
bl blau
gr/ge grün/gelb
L1,N,PE Netz 230V/50Hz
1
2
3
4
5
6
5
7
Illustration, left: Plug connection (drive side)
Illustration, right: Coupling connection (mains supply)
1 blue (neutral conductor)
2 black
3 brown
Green-yellow
Fig. 4 Connection diagram SunTop 230 V/50 Hz and cable
assignment when using Hirschmann plug connec-
tion STAS-3
Important
The motor controls in the up/down direction must be locked
against each other.
5.4 Parallel circuit
Important
You can connect several SunTop drives in parallel. Please
note the maximum switching capacity of the control unit.
5.5 Commissioning
Important
The drive is in commissioning mode when delivered.
►
The end positions must be adjusted using the
elero
assembly cable
►
The assembly cable may only be connected to commis-
sion the drive and for adjustment operations
%ODX1HXWUDOOHLWHU
6FKZDU]
%UDXQ
*UQJHOE
HOHUR
%ODX1HXWUDOOHLWHU
6FKZDU]
%UDXQ
*UQJHOE
Fig. 5 Connection for assembly cable
►
Switch on mains.
►
You can now set the end positions with the
elero
assem-
bly cable.
1
Winding thermostat
2
Electronics
3
Junction box
4
Switch box
5
Interlocked venetian
blind push button/switch
6
Drive
7
Capacitor
sw
black
br
brown
bl
blue
gr/ge
green/yellow
3
2
1
6 | EN
©
elero
GmbH
Assembly: Electrical connection | Adjusting the end positions
5.2 Electrical connection
WARNING
Faulty electrical connections constitute a fatal hazard.
Risk of electric shock.
►
Prior to initial commissioning, check the PE wire is cor-
rectly connected.
ATTENTION
Damage to the SunTop due to incorrect electrical
connection.
►
Prior to initial commissioning, check the PE wire is
correctly connected.
Ingress of moisture will damage or even destroy the
SunTop.
►
For devices with protection class IP44, the customer-side
connection of the cable ends or plugs (cable feed-
through) can also be implemented according to protection
class IP44.
Damage or destruction of the SunTop for variants with
230 V 1 AC due to incorrect activation.
►
Switches with an OFF presetting (dead-man's switches)
for drives are to be attached within visible range of the
SunTop but away from spontaneously moving parts and
at a height of more than 1.5 m.
Damage to the blind due to incorrect travel direction.
►
The assignment of the UP/DOWN travel direction must
be checked after the electrical connection has been
established.
Misalignment of the end positions on the drive.
►
Misalignment of the end positions is indicative of a faulty
electrical connection. Readjusting the end positions is not
sufficient in this scenario as the end positions will simply
become misaligned again. The drive must then be re-
placed and the cause of the problem rectified.
Important
All applicable standards and regulations must be observed
during the electrical installation.
If the drive is connected to a control unit, the operating
instructions for the control unit must be observed.
There is generally no need to plug the connecting cable
and plug in and out again for the electrical connection.
Depending on the mounting or adapter plate used, the
plate will need to be removed prior to cable replacement.
This applies in particular to the SunTop type S.
Connect only in de-energised state. To do this, switch
the drive cable so it is de-energised.
1 Press locking mechanism on the motor cable plug to-
wards the cable using a screwdriver.
2
Pull out the plug.
3
Insert the motor cable plug until the lock engages.