5.6  Setting of end positions and strain relief 

Important preliminary consideration: 

The relief for an end position produces a low material load 

on the drive and blind. It counteracts the tensile forces act-

ing on the blind at the upper end position and the compres-

sive forces acting on the lower end position by momentarily 

changing the travel direction. 

Decide on a specific relief function before setting the end 

position (different combination options as per the following 

designs):  

This will save you unnecessary configuration outlay! 

With the assembly cable connected, press one of the travel 

keys until the drive signals the transition to programming 

mode by a short, automatic stop. You can now program the 

end positions. The setting mode is finished after both end 

positions have been set. 

5.6.1  Relief function for end position(s) 

If an end position was taught in at a limit stop, a relief can 

also be enabled for the blind. 

Important 

The relief function (for variants B to D) is activated in one 

step when programming the end positions (see chapters 

5.6.7 to 5.6.9)! 

5.6.2  Relief function at upper end position 

For variant B (see chapter 5.6.7)  

and variant C (see chapter 5.6.8): 

Activate relief function at upper end position 

Use the assembly cable while holding down the 

UP

 

button ▲ from instruction 

 (chapters 5.6.7 and 

5.6.8) to also press the 

DOWN

 button ▼ (simul

-

taneously), and hold down both buttons until the 

blind stops. 

The relief function at the upper end position is activated. 

5.6.3  Relief function at lower end position 

For variant C (see chapter 5.6.8) and variant D 

(see chapter 5.6.9): 

Activate relief function at lower end position 

Use the assembly cable while holding down the 

DOWN

 button ▼ from instruction 

③ 

(chapters 

5.6.8 and 5.6.9) to also press the 

UP

 button ▲ 

(simultaneously), and hold down both buttons until 

the blind stops. 

The relief function at the lower end position is activated. 

5.6.4  Changing/deleting the end positions and 

deleting the relief function 

It is not possible to change or delete individual end posi-

tions. This is always done in pairs (upper and lower end 

position simultaneously). 
When the end positions are deleted, the setting for the 

optional relief function will also be discarded. 

Important 

The blind protection system is only adapted to the blind 

after a complete, uninterrupted upwards and downwards 

travel. 

Changing/deleting the end positions 

Starting from a central position of the blind, use the 

assembly cable to simultaneously press both direc-

tion buttons (▲ and ▼), and hold them down until the 

drive briefly moves up and down. 

The end position settings have been deleted. 
The end positions may be readjusted. 

5.6.5  Four variants of end position settings 

Four combinations of end position settings can be chosen. 

End position settings (4 variants) 

Upper and lower end position freely adjustable 

B

Fixed upper end position, lower end position freely 

adjustable 

Fixed upper and lower end position 

D

Upper end position freely adjustable, fixed lower end 

position

Fig. 6    End position setting variants for the SunTop 

5.6.6  Variant A:  Upper and lower end position 

freely adjustable 

Variant A:  

Upper and lower end position freely adjustable 

①  

Starting from a central position of the blind, press 

the 

UP

 button▲ with the assembly cable until the 

blind has reached the desired upper end position. 

The drive begins to travel, briefly stops and travels 

further (for as long as the UP button ▲ remains 

pressed). 

Corrections are possible using the ▲ and ▼ buttons. 

②  

Press the 

DOWN

 button ▼ until the drive stops 

automatically. 
The upper end position has been set. 

③  

Press the 

DOWN

 button ▼ again until the blind has 

reached the desired lower end position. 

The drive begins to travel, briefly stops and travels 

further (for as long as the 

DOWN

 button ▲ remains 

pressed). 

Corrections are possible using the ▲ and ▼ buttons. 

④ 

Press the 

UP

 button ▲ until the drive stops auto

-

matically. 
The lower end position has been set. 

Adjustment of the variant A end position is complete. 

Fig. 7    End position setting, variant A: 

 © 

elero

 GmbH

  

EN | 7

End position adjustment | Relief function 

Summary of Contents for SunTop

Page 1: ...ion of conformity see EC Declaration of Conformity All in Contents 1 Operating and assembly instructions 1 2 General information on these instructions 1 2 1 Standards and guidelines 1 2 2 Intended use...

Page 2: ...the regulations on accident prevention environmental protection and occupational health and safety applicable at the location of use must be observed and adhered to The regulations and standards for...

Page 3: ...l as inform his her customers regarding the operating and maintenance conditions for this product 3 4 General duties of the plant operator The plant operator is obliged to only operate the product in...

Page 4: ...en out of operation immedi ately and the plant operator informed accordingly No changes conversions or attachments may be made to the product without the permission of the manufacturer The system must...

Page 5: ...be implemented immediately after removing the SunTop from the original packaging The drive must be installed so that it cannot get wet Damage to the blind due to incorrect assembly Observe the notes...

Page 6: ...ire is correctly connected Ingress of moisture will damage or even destroy the SunTop For devices with protection class IP44 the customer side connection of the cable ends or plugs cable feed through...

Page 7: ...positions and deleting the relief function It is not possible to change or delete individual end posi tions This is always done in pairs upper and lower end position simultaneously When the end positi...

Page 8: ...d Check mains voltage Allow drive to cool down 8 EN elero GmbH End position settings 5 6 7 Variant B Fixed upper end position lower end position freely adjustable Variant B Fixed upper end position lo...

Page 9: ...s that can be reused if dis mantled by a specialist company Please note the local regulations on disposal of packaging materials and old appliances On disassembly additional dangers must be reckoned w...

Page 10: ...44 44 Limit switch range revolutions 80 40 Operating time min S2 4 4 Length C mm 534 534 Length D mm 517 517 Length E mm 11 11 Weight kg 1 2 1 3 Thermal operating condition C 20 60 20 60 Conformity No...

Page 11: ...er mm 50 50 50 50 50 50 50 Protection class IP 44 44 44 44 44 44 44 Limit switch range revolutions 40 40 40 40 40 40 40 Operating time min S2 5 5 5 4 4 5 4 Length C mm 466 466 526 526 516 546 546 Leng...

Page 12: ...4 Rated current A 1 20 1 65 2 20 Rated power consumption W 280 380 490 Shaft diameter mm 63 63 63 Protection class IP 44 44 44 Limit switch range revolutions 80 40 40 Operating time min S2 4 4 4 Lengt...