22
EN
DD51-E
Direct drive electronic position indicators
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
It is possible to change the function
of the keys combination by setting the
parameter
0 _ 0 _ _
The available options are:
-
L_OrG
: the reference value and the compensation
value are set as shown above. Choose the desired
offset among the 10 available values, then press the
key
to confirm;
-
OFF
: the keys combination
+
is not
associated to any function in the operating mode
For programming the parameters listed above see
paragraph 8.2.
7.4 Direct programming of the absolute reference
value (source) – of the compensation value (offset)
– of the reading after one revolution
The function of the keys combination allows
direct access to the programming of one
of the following parameters, depending on the value
assigned to parameter
0 _ _ _ 0
.
The available options are:
-
P_OrG
: direct programming of the absolute reference
value (OrG parameter)
-
P_StP
: direct programming of the reading after one
revolution (StEP parameter)
-
P_OFS
: direct programming of the compensation
value (OFFS parameter)
-
OFF
: the keys combination
+
is not linked
to any function in the operating mode
For programming the parameters listed above see
paragraph 8.2.
0 _ 0 _ _
+