27
DD51-E
Direct drive electronic position indicators
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
EN
Parameter Description
Available options
Standard
value
_ _ 0 _ _
Key function
ArCLr
: switching
from
ABS
to
REL
the
counter is set to zero.
Ar
: switching from
ABS
to
REL
the
counter is not set
to zero.
OFF
: the key is
not assigned to
any function in the
operating mode
ArCLr
_ _ _ _ 0
Key function
ALL
: selectable
units of measure: mm,
inch, D
nodEG
: selectable
units of measure:
mm, inch
OFF
: the key does
not allow the unit of
measure conversion
ALL
0 _ 0 _ _
Key
combination
function
+
L_OrG
: the key
combination sets the
absolute value to the
sum of
OrG
+
OFFS
parameters
OFF
: the key
combination is
not assigned to
any function in the
operating mode
L_OrG