23
EN
DD52R-E-RF
Electronic position indicators
Data transmission via radio frequency
Electronic position indicators
Data transmission via radio frequency
Models all rights reserved in accordance with the law.
Always mention the source when reproducing our drawings.
-
LOAd_t
: choose one of the 32 available target positions,
then press
to confirm
-
PrOG_t
: choose to program one of the 32 available target positions,
then press
to start programming
7.7 Battery replacement
The internal lithium CR2477 - 3.0 V battery ensures over 3 years battery life.
The symbol is shown on the display when the battery replacement is required.
The replacement is made by simply removing the front cover without disassembly
of the indicator from the control shaft and keeping unchanged all the configuration
parameters.
To simply remove the battery from the battery compartment, we recommend the
use of a magnet.
8. Programming mode
Press the key
for 3 seconds to enter the programming mode. Depending on
the setting of
PASS
parameter (see table on page 28), the system may require
you to enter a password.
Press the key
to scroll through the list of parameters.
Press the key
to exit the programming mode. The programming mode is
automatically dropped after 30 seconds of inactivity.